International Peer-Reviewed JournalOpen AccessISSN 2456-8880
irejournals@gmail.com+91-7433024337

Home / Current Issue / Paper 1700766

1700766 Vol 2 · Issue 4 Download Paper

RECENT TREND IN PILOT BASED POWER TRANSMISSION AND DISTRIBUTION PROTECTION

Ogwata C.M Dr. Ezechukwu A.O

Subject area: Science,Engineering and Technology  ·  Area of research: Electrical Engineering

Abstract

The development of protection schemes for transmission and distribution lines began more than a hundred years ago, with voltage restrained time over current relay being one of the more prominent attempts in history. However, phase and neutral overcurrent protection, in its simplest forms, offered a significant disadvantage for line protection because its fault coverage of the protected circuit is dependent on source impedance variations. Since then, the line protection schemes have faced undeterred evolution, which essentially provides a rather simplistic and more efficient protection schemes available today.

Keywords

pilot, protection, transmission, distribution

References

[1] G. Ziegler, Numerical Differential Protection: Principles and Applications, Nuremberg, Germany: Siemens AG, Jul. 2005

[2] P.M. Anderson, Power System Protection, McGraw-Hill /IEEE Press, New York, NY, 1999.

[3] IEEE Power System Relaying Committee Report, “Line protection design trends in the USA and Canada,” IEEE Transactions on Power Delivery, Vol. 3, No 4, October 1988, pp. 1530-1535

[4] J. Tan, D. Tholomier, G. Bin, andW. Hua, “Sensitivity and stability of superimposed component based directional comparison protection,” in Proc. Can. Conf. Elect. Comput. Eng., 2007, pp. 280–283.

[5] K. V. Babu, M. Tripathy, A. K. Singh ‘Recent techniques used in transmission line protection: a review’ International Journal of Engineering, Science and Technology Vol. 3, No. 3, 2011, pp. 1-8

[6] C. Dzienis , M. Kereit ,‘An Experimental Analysis of High-Speed-Distance Protection’ October 2010 Source: IEEEXplore

[7] J. Roberts, D. Tziouvaras, G. Benmouyal, ‘The Effect of Multiprinciple Line Protection on Dependability and Security’55th Annual Georgia Tech Protective Relaying Conference, May 2001,

[8] J. Roberts, A. Guzmán, ‘Directional Element Design and Evaluation’ 49th Annual Georgia Tech Protective RelayingConference, May 1995 and revised edition released August 2006

[9] Power System protection Principles by Alstom, Chapter 11 (Distance Protection)

[10] M. G. Adamiak, Dr. W. Premerlani, G. E. Alexander, ‘A New Approach to Current Differential Protection for Transmission Lines’ Electric council of new England protective relaying committee meeting october 22-23, 1998 portsmouth.

[11] S. HHasanKazmi, ‘Piloted Protection Solutions For Distribution Networks With Integrated Distributed Energy Resources’ M.Sc. Thesis. Norwegian University of Science & Technology, August 2017

How to cite this paper

Ogwata C.M, Dr. Ezechukwu A.O "RECENT TREND IN PILOT BASED POWER TRANSMISSION AND DISTRIBUTION PROTECTION" Iconic Research And Engineering Journals Volume 2 Issue 4 2018 Page 66-69
Ogwata C.M, Dr. Ezechukwu A.O "RECENT TREND IN PILOT BASED POWER TRANSMISSION AND DISTRIBUTION PROTECTION" Iconic Research And Engineering Journals, vol. 2, no. 4, Oct. 2018
Ogwata C.M, Dr. Ezechukwu A.O (2018). RECENT TREND IN PILOT BASED POWER TRANSMISSION AND DISTRIBUTION PROTECTION. Iconic Research And Engineering Journals, 2(4).
Ogwata C.M, Dr. Ezechukwu A.O "RECENT TREND IN PILOT BASED POWER TRANSMISSION AND DISTRIBUTION PROTECTION" Iconic Research And Engineering Journals, vol. 2, no. 4, Oct. 2018.
@article{1700766,
      author = {Ogwata C.M, Dr. Ezechukwu A.O},
      title = {RECENT TREND IN PILOT BASED POWER TRANSMISSION AND DISTRIBUTION PROTECTION},
      journal = {Iconic Research And Engineering Journals},
      year = {2018},
      volume = {2},
      number = {4},
      pages = {66-69},
      issn = {2456-8880},
      url = {https://www.irejournals.com/formatedpaper/1700766.pdf},
      abstract = {The development of protection schemes for transmission and distribution lines began more than a hundred years ago, with voltage restrained time over current relay being one of the more prominent attempts in history. However, phase and neutral overcurrent protection, in its simplest forms, offered a significant disadvantage for line protection because its fault coverage of the protected circuit is dependent on source impedance variations. Since then, the line protection schemes have faced undeterred evolution, which essentially provides a rather simplistic and more efficient protection schemes available today.},
      keywords = {pilot, protection, transmission, distribution},
      month = {October},
  }