International Peer-Reviewed JournalOpen AccessISSN 2456-8880
irejournals@gmail.com+91-7433024337

Home / Current Issue / Paper 1700766

1700766PublishedVol 2 · Issue 4

RECENT TREND IN PILOT BASED POWER TRANSMISSION AND DISTRIBUTION PROTECTION

Ogwata C.M Dr. Ezechukwu A.O

Subject area: Science,Engineering and Technology  ·  Area of research: Electrical Engineering

Abstract

The development of protection schemes for transmission and distribution lines began more than a hundred years ago, with voltage restrained time over current relay being one of the more prominent attempts in history. However, phase and neutral overcurrent protection, in its simplest forms, offered a significant disadvantage for line protection because its fault coverage of the protected circuit is dependent on source impedance variations. Since then, the line protection schemes have faced undeterred evolution, which essentially provides a rather simplistic and more efficient protection schemes available today.

Keywords

pilot, protection, transmission, distribution

How to cite this paper

Ogwata C.M, Dr. Ezechukwu A.O "RECENT TREND IN PILOT BASED POWER TRANSMISSION AND DISTRIBUTION PROTECTION" Iconic Research And Engineering Journals Volume 2 Issue 4 2018 Page 66-69
Ogwata C.M, Dr. Ezechukwu A.O "RECENT TREND IN PILOT BASED POWER TRANSMISSION AND DISTRIBUTION PROTECTION" Iconic Research And Engineering Journals, vol. 2, no. 4, Oct. 2018
Ogwata C.M, Dr. Ezechukwu A.O (2018). RECENT TREND IN PILOT BASED POWER TRANSMISSION AND DISTRIBUTION PROTECTION. Iconic Research And Engineering Journals, 2(4).
Ogwata C.M, Dr. Ezechukwu A.O "RECENT TREND IN PILOT BASED POWER TRANSMISSION AND DISTRIBUTION PROTECTION" Iconic Research And Engineering Journals, vol. 2, no. 4, Oct. 2018.
@article{1700766,
      author = {Ogwata C.M, Dr. Ezechukwu A.O},
      title = {RECENT TREND IN PILOT BASED POWER TRANSMISSION AND DISTRIBUTION PROTECTION},
      journal = {Iconic Research And Engineering Journals},
      year = {2018},
      volume = {2},
      number = {4},
      pages = {66-69},
      issn = {2456-8880},
      url = {https://www.irejournals.com/formatedpaper/1700766.pdf},
      abstract = {The development of protection schemes for transmission and distribution lines began more than a hundred years ago, with voltage restrained time over current relay being one of the more prominent attempts in history. However, phase and neutral overcurrent protection, in its simplest forms, offered a significant disadvantage for line protection because its fault coverage of the protected circuit is dependent on source impedance variations. Since then, the line protection schemes have faced undeterred evolution, which essentially provides a rather simplistic and more efficient protection schemes available today.},
      keywords = {pilot, protection, transmission, distribution},
      month = {October},
  }