Abstract
In modern architecture there is a high probability of fire occurrence which leads to huge losses in people's lives and property. In order to reduce the fire in the buildings and forests automatic fire alarm equipment placed into a necessity. This paper discusses the real time fire detection, the composition and working principle. The system will be collected through the fire alarm detector to the fire such information will be sent to the fire alarm control through GSM, and then start from the controller, sound, alarm and other devices, and automatically print a fire information. This paper describes the overall structure of the real time fire detection. The detection of fire will help the mankind to safeguard from the huge losses.
Keywords
GSM, Buzzer, Arduino uno, DC 5v motor and Fire sensor
References
[1] Cytron USB to UART Converter User Manual, Cytron Technology Inc., 2011, pp. 1-23.
[2] S. D. Dissanayake; P. P. C. R. Karunasekara; ,D. D. Lakmanaarachchi; A. J. D. Rathnayaka; A. T. L. K. Samarasinghe, “ZigBee wireless vehicular identification and authentication system,” International Conference on Information and Automation for Sustainability, 2008, pp.257-260.
[3] F. He; Z. Du; Y. Sun, “Indoor dangerous gas environment detected by mobile robot,”in 2009 IEEE International Conference on Robotics and Biomimetic (ROBIO), pp. 396-401.
[4] M. F. Jan; Q. Habib; M. Irfan, Jan, M.F.; Habib, Q.; Irfan, M.; Murad, M.; Yahya, K.M.; Hassan, G.M., "Carbon monoxide detection and autonomous countermeasure system for a steel mill using Wireless Sensor and Actuator Network," in 2010 6th International Conference on Emerging Technologies (ICET), pp. 405-409
[5] A. Somov; A. Baranov; A. Savkin; D. Spirjakin; A. Spirjakin; R. Passerone. (2011, Nov). Development of wireless sensor network for combustible gas monitoring. Sensors & Actuators A: Physical [Online]. 171(2), pp. 1-8.Available: http://www.sciencedirect.com/science/article/pii/S0924424711004596
[6] V. Jelicic; M. Magno; G. Paci; D. Brunelli; L. Benini, "Design, characterization and management of a wireless sensor network for smart gas monitoring,"in 2011 4th IEEE Int. Workshop on Adv. in Sensors and Interfaces (IWASI), pp. 115-120
How to cite this paper
@article{1702346,
author = {Y. V. Sai Teja, Sivaiah Naali, T. Randdhir Reddy, R H V N S Sai Nikhil, P. Manikanta Reddy},
title = {Real Time Fire Detection},
journal = {Iconic Research And Engineering Journals},
year = {2020},
volume = {3},
number = {12},
pages = {29-32},
issn = {2456-8880},
url = {https://www.irejournals.com/formatedpaper/1702346.pdf},
abstract = {In modern architecture there is a high probability of fire occurrence which leads to huge losses in people's lives and property. In order to reduce the fire in the buildings and forests automatic fire alarm equipment placed into a necessity. This paper discusses the real time fire detection, the composition and working principle. The system will be collected through the fire alarm detector to the fire such information will be sent to the fire alarm control through GSM, and then start from the controller, sound, alarm and other devices, and automatically print a fire information. This paper describes the overall structure of the real time fire detection. The detection of fire will help the mankind to safeguard from the huge losses. },
keywords = {GSM, Buzzer, Arduino uno, DC 5v motor and Fire sensor},
month = {June},
}