Home / Current Issue / Paper 1703541
Proposed Synergy of Electrical Energy Sources in the Administrative Building of the Educational Institution in Bacolor Pampanga, Philippines
Subject area: Science,Engineering and Technology · Area of research: Renewable Energy
Abstract
The use of electricity has become significant in modern society as it serves various purposes. However, power interruptions are unavoidable and have a negative impact on people's daily activities, particularly in schools and industries, because electricity is used in almost every aspect of life. Specifically, a lack of electric energy can result in lower productivity because it incapable workers of properly performing their duties. This feasibility study proposes continuous energy supply to offices and other important building facilities for the institution?s administrative building in Bacolor, Pampanga. The analysis involves explicitly identifying the equipment and other materials used in the electrical energy synergy plan, objective evaluation of the initial investment, calculating the payback period, and determining the return on investment. The design used in this research is a grid-tied system with solar energy as the primary source, utility as secondary, and Gen-set for a backup power system in case the utility fails. This study involves assessing site suitability, solar access, shadowing considerations, and other factors. The results obtained 120 pieces of solar panels of 500 Wp each, a 60kW inverter, and a 100 kVA generator were calculated to run the system for the total demand of 57.2125 kW of the administrative building. The payback period is 3.97 years and a return of investment is P 13,744,020 for 25 years. If implemented, the project will solve the institution's electric power problem at the Administrative Building by providing stable, sufficient, and dependable 24-hour electricity.
Keywords
Explicit, Productivity, Synergy, Utility
References
[1] Daniel Day, Why is Electricity Important?, (2018), R Turner Electric Company Inc, Retrieved from https://www.rturnerelectric.com/why-is- electricity-important/
[2] Fickett, A. P., Gellings, C. W., & Lovins, A. B. (1990). Efficient use of electricity. Scientific American, 263(3), 64-75.
[3] Johnson, D. O., Hassan, K. A., Okusanya, S. O., & Oladapo, J. O. (2020). Solar Electricity System Design for Administrative Buildings. FUOYE Journal of Engineering and Technology, 5(1).
[4] Arante, R. B. INTERNATIONAL JOURNAL OF ENGINEERING SCIENCES & RESEARCH TECHNOLOGY PHOTOVOLTAIC POWER SYSTEM DESIGN FOR CARAGA STATE UNIVERSITY CABADBARAN CAMPUS, AGUSAN DEL NORTE, PHILIPPINES.
[5] Mathew, P., Sanchez, L., Lee, S. H., & Walter, T. (2021). Assessing the energy resilience of office buildings: Development and testing of a simplified metric for real estate stakeholders. Buildings, 11(3), 96.
[6] Achalu, S. (2020). THE ECONOMIC IMPACT OF POWER INTERRUPTION ON INDUSTRIAL CONSUMERS: A CASE STUDY IN YES BRANDS FOODS & BEVERAGES PLC AND OXFORD AMALGATED PLC (Doctoral dissertation)
[7] Deeba, S. R., Sharma, R., Saha, T. K., Chakraborty, D., & Thomas, A. (2016). Evaluation of technical and financial benefits of battery‐based energy storage systems in distribution networks. IET Renewable Power Generation, 10(8), 1149-1160.
[8] Knier, G. (2002). How do photovoltaics work. Science@ NASA.
[9] Adell Puigdevall, C., & Fonseca Benharref, N. (2017). Design and construction of a Mobile Renewable Energy Unit.
[10] Ahmed, M. M., & Sulaiman, M. (2003, December). Design and proper sizing of solar energy schemes for electricity production in Malaysia. In Proceedings. National Power Engineering Conference, 2003. PECon 2003. (pp. 268-271). IEEE.
[11] Harajli, H., Kabakian, V., El-Baba, J., Diab, A., & Nassab, C. (2020). Commercial-scale hybrid solar photovoltaic-diesel systems in select Arab countries with weak grids: an integrated appraisal. Energy policy, 137, 111190.
[12] Waseem, I., Pipattanasomporn, M., & Rahman, S. (2009, July). Reliability benefits of distributed generation as a backup source. In 2009 IEEE Power & Energy Society General Meeting (pp. 1-8). IEEE.
[13] Faraji, J., Babaei, M., Bayati, N., & A Hejazi, M. (2019). A comparative study between traditional backup generator systems and renewable energy based microgrids for power resilience enhancement of a local clinic. Electronics, 8(12), 1485.
[14] Christian Brown, How to Size a PV System from an Electricity Bill, (2016), aurora, Retrieved from https://www.aurorasolar.com/blog/how-to- size-a-pv-system-from-an-electricity-bill/
[15] How to Design Solar PV System - Guide for sizing your solar photovoltaic system, (2015), Leonics.com, Retrieved from https://www.leonics.com/support/article2 _12j/articles2_12j_en.php
[16] El-Hefnawi, S. H. (1998). Photovoltaic diesel- generator hybrid power system sizing. Renewable Energy, 13(1), 33-40.
[17] Standard Electrical Formulas Used for Power Consumption Calculations, (2022), Generator source, Retrieved from https://www.generatorsource.com/Formula_Cha rt.aspx
[18] Solar Panel Spacing Gaps (Why They Are Important), (2022), Sol Voltaics, Retrieved from https://solvoltaics.com/
[19] Wire Sizing Chart for 12V, 24V, and 48V DC Systems, (2022), altE, Retrieved from https://www.altestore.com/diy-solar- resources/wire-sizing-tool-for-12-24-and-48- volt-dc-systems/
[20] A principle of selecting DC Isolators for PV Systems, (2015), Projoy electric, Retrieved from https://en.projoy-electric.com/news/a-principle- of-selecting-dc-isolators-for-pv-syste.html
[21] Mark Dziedzic, How to properly size surge protective devices, (2021), Plant Engineering, Retrieved from https://www.plantengineering.com/articles/how- to-properly-size-surge-protective-devices/
[22] Michael Wilson, How do I size an automatic transfer switch, (2020), Norman- Restaurant.com, Retrieved from https://norman- restaurant.com/how-do-i-size-an-automatic- transfer-switch/
[23] What would be the annual maintenance cost for a solar PV system, (2022), MySun, Retrieved from https://www.itsmysun.com/faqs/what- would-be-the-annual-maintenance-cost-for-a- solar-pv-system/
[24] Dricus De Rooij, Labor Costs for Installing Solar Panels, (2012), SinoVoltaics, Retrieved from https://sinovoltaics.com/learning- center/consumers/labor-costs-installing-solar- panels/
[25] Solar ROI Calculator: Are Solar Panels Worth it?, (2022), Unbound Solar, Retrieved from https://unboundsolar.com/solar- information/return-on-solar-investment
How to cite this paper
@article{1703541,
author = {John Patrick R. Alejo, Gerome M. David, Mark Allem D. Punzalan, Jonh Loyd H. Tulabut, Alma L. Tangcuangco; Ralph Laurence D. Parungao},
title = {Proposed Synergy of Electrical Energy Sources in the Administrative Building of the Educational Institution in Bacolor Pampanga, Philippines},
journal = {Iconic Research And Engineering Journals},
year = {2022},
volume = {5},
number = {12},
pages = {181-189},
issn = {2456-8880},
url = {https://www.irejournals.com/formatedpaper/1703541.pdf},
abstract = {The use of electricity has become significant in modern society as it serves various purposes. However, power interruptions are unavoidable and have a negative impact on people's daily activities, particularly in schools and industries, because electricity is used in almost every aspect of life. Specifically, a lack of electric energy can result in lower productivity because it incapable workers of properly performing their duties. This feasibility study proposes continuous energy supply to offices and other important building facilities for the institution?s administrative building in Bacolor, Pampanga. The analysis involves explicitly identifying the equipment and other materials used in the electrical energy synergy plan, objective evaluation of the initial investment, calculating the payback period, and determining the return on investment. The design used in this research is a grid-tied system with solar energy as the primary source, utility as secondary, and Gen-set for a backup power system in case the utility fails. This study involves assessing site suitability, solar access, shadowing considerations, and other factors. The results obtained 120 pieces of solar panels of 500 Wp each, a 60kW inverter, and a 100 kVA generator were calculated to run the system for the total demand of 57.2125 kW of the administrative building. The payback period is 3.97 years and a return of investment is P 13,744,020 for 25 years. If implemented, the project will solve the institution's electric power problem at the Administrative Building by providing stable, sufficient, and dependable 24-hour electricity. },
keywords = {Explicit, Productivity, Synergy, Utility},
month = {June},
}