The thermodynamic evaluation of the effect of ambient temperature in the performance of an air conditioning system in a temperate region was carried out. A 20 ton capacity air conditioner was designed and used for the experiment. Thermodynamics analysis of the system was carried out using the PH and TS diagram. The coefficient of performance (COP) was calculated to be 2.02. The effect of the ambient temperature on the enthalpy value after compression, the COP and the exergy of the system designed was studied. The enthalpy and the exergy of the system were seen to be increasing with increase in ambient temperature. While the COP decreased as the ambient temperature increases. The work done on the compressor was gotten as 34.85 J.
Keywords
Ambient Temperature, Temperate Region, Air Conditioning, COP, Thermodynamics
References
[1] Wu, J., Yang, L. & Hou, J. 2012. Experimental performance study of a small wall room air conditioner retrofitted with R290 and R1270. International Journal of Refrigeration, 35, 18601868.
[2] Kim, D. H., Park, H. S. & Kim, M. S. 2014. The effect of the refrigerant charge amount on single and cascade cycle heat pump systems. International Journal of Refrigeration, 40, 254-268
[3] Ahmad Sharifian1, Jeri Tangalajuk Siang 2022. Impacts of room temperature on the performance of a portable propane air conditioner
[4] Teng, T.-P., Mo, H.-E., Lin, H., Tseng, Y.-H., Liu, R.-H. & Long, Y.-F. 2012. Retrofit assessment of window air conditioner. Applied Thermal Engineering, 32, 100-107.
[5] Corberán, J.-M., Martínez-Galván, I., Martínez-Ballester, S., Gonzálvez-Maciá, J. & Royo-Pastor, R. 2011. Influence of the source and sink temperatures on the optimal refrigerant charge of a waterto-water heat pump. International Journal of Refrigeration,34, 881-892.
[6] Nilpueng, K., Supavarasuwat, C. & Wongwises, S. 2011. Performance characteristics of HFC134a and HFC-410A refrigeration system using a short-tube orifice as an expansion device. Heat and mass transfer, 47, 1219-1227
[7] Mohd Hazwan Yusof, Sulaiman Mohd Muslim , Muhammad Fadhli Suhaimi1 , and Mohamad Firdaus Basrawi1 (2018). The Effect of Outdoor Temperature on the Performance of a Split-Unit Type Air Conditioner Using R22 Refrigerant MATEC Web of Conferences 225, 02012
[8] Mukhamad Suhermanto1, Murat Hoşöz2 and M. Celil Aral (2016) Effect of Ambient Temperature on the Performance Characteristics of Automotive Air Conditioning System Using R1234yf and R134a: Energy and Exergy-based approaches. Proceedings of the International Mechanical Engineering and Engineering Education Conferences (IMEEEC 2016)
[9] Takdanai Suparos, Sirichai Thepa, Nat Kasayapand (2022), Energy and Exergy Analysis of an air conditioning system with solar collector. RMUTR and RICE International Conference pp 81-96
[10] Mariagiovanna Minutillo, Alessandra Perna and Alessandro Sorce (2019) Exergy analysis of a biomass-based multienergy system E3S Web of Conferences 113, 02017
[11] Kingsley Madu (2018) design of a 10 ton capacity standard vapour compression air-conditioning plant for application in a mini auditorium, in nigeria International Journal of Innovation and Sustainability
[12] Paula Pratolongo, Andrew plater (2019) coastal weastlands (second edition)
How to cite this paper
@article{1705365,
author = {Chike Martin Atah, Kingsley E. Madu},
title = {Thermodynamics Evalution of the Effect of Ambient Temperature in the Performance of Airconditioning System in the Temperate Region},
journal = {Iconic Research And Engineering Journals},
year = {2024},
volume = {7},
number = {7},
pages = {358-364},
issn = {2456-8880},
url = {https://www.irejournals.com/formatedpaper/1705365.pdf},
abstract = {The thermodynamic evaluation of the effect of ambient temperature in the performance of an air conditioning system in a temperate region was carried out. A 20 ton capacity air conditioner was designed and used for the experiment. Thermodynamics analysis of the system was carried out using the PH and TS diagram. The coefficient of performance (COP) was calculated to be 2.02. The effect of the ambient temperature on the enthalpy value after compression, the COP and the exergy of the system designed was studied. The enthalpy and the exergy of the system were seen to be increasing with increase in ambient temperature. While the COP decreased as the ambient temperature increases. The work done on the compressor was gotten as 34.85 J.},
keywords = {Ambient Temperature, Temperate Region, Air Conditioning, COP, Thermodynamics},
month = {January},
}