Abstract

The integration of renewable energy sources into high-voltage (HV) transmission systems introduces complex power quality challenges due to the widespread use of power electronic converters in wind and solar generation. These converter-dominated units significantly affect harmonic characteristics, interharmonic propagation, voltage stability, and sub-synchronous oscillation behavior. The analysis presented in this study synthesizes the major power quality impacts observed in modern transmission grids with increasing renewable penetration. Results show that harmonic distortion and resonance risks intensify in networks where underground cables, MMC-HVDC links, and large inverter-based resources interact, shifting system impedance and lowering resonance frequencies. Voltage fluctuations and reactive power imbalance caused by large-scale wind integration further degrade stability, particularly in weak grids with low short-circuit strength. Sub-synchronous resonance mechanisms differ between turbine technologies, where DFIG units primarily trigger induction-generator-based SSR, while full-converter turbines exhibit control-interaction-driven SSCI. Mitigation strategies identified as most effective include MMC-HVDC systems, STATCOM and UPFC-based dynamic compensation, Battery Energy Storage Systems (BESS), and grid-forming inverter control. Overall, advanced converter control, coordinated reactive power support, and harmonic-aware transmission planning are essential to ensure secure and reliable operation in high-renewable HV networks.

Keywords

Harmonic Distortion, Power Quality, Renewable Energy, Sub-Synchronous Resonance, Transmission Lines

References

[1] Arena, M., & Azzone, G. (2009). Identifying organizational drivers of internal audit effectiveness. International Journal of Auditing, 13(1), 43–60.

[2] Basel Committee on Banking Supervision. (2015). Corporate governance principles for banks. Bank for International Settlements.

[3] Basel Committee on Banking Supervision. (2021). Principles for operational resilience. Bank for International Settlements.

[4] Beasley, M. S., Branson, B. C., & Hancock, B. V. (2015). ERM and the board of directors. Committee of Sponsoring Organizations of the Treadway Commission (COSO).

[5] Bromiley, P., McShane, M., Nair, A., & Rustambekov, E. (2015). Enterprise risk management: Review, critique, and research directions. Long Range Planning, 48(4), 265–276.

[6] Committee of Sponsoring Organizations of the Treadway Commission (COSO). (2017).

[7] Enterprise Risk Management: Integrating with Strategy and Performance. COSO.

[8] DeFond, M. L., & Zhang, J. (2014). A review of archival auditing research. Journal of Accounting and Economics, 58(2–3), 275–326.

[9] Financial Stability Board. (2013). Principles for an effective risk appetite framework. Bank for International Settlements.

[10] Gendron, Y., & Bédard, J. (2006). On the constitution of audit committee effectiveness.

[11] Accounting, Organizations and Society, 31(3), 211–239.

[12] Gramling, A. A., Maletta, M. J., Schneider, A., & Church, B. K. (2004). The role of the internal audit function in corporate governance. Journal of Accounting Literature, 23, 194–244.

[13] Institute of Internal Auditors (IIA). (2020). The three lines model: An update of the three lines of defense. IIA Global.

[14] Institute of Internal Auditors (IIA). (2023). International Standards for the Professional Practice of Internal Auditing. IIA Global.

[15] Kaplan, R. S., & Mikes, A. (2012). Managing risks: A new framework. Harvard Business Review, 90(6), 48–60.

[16] Mikes, A., & Kaplan, R. S. (2015). When one size doesn’t fit all: Evolving directions in the research and practice of enterprise risk management. Journal of Applied Corporate Finance, 27(1), 37–40.

[17] Power, M. (2007). Organized uncertainty: Designing a world of risk management. Oxford University Press.

[18] Sarens, G., & De Beelde, I. (2006). The relationship between internal audit and senior management: A qualitative analysis of expectations and perceptions. International Journal of Auditing, 10(3), 219–241.

[19] Sarens, G., De Beelde, I., & Everaert, P. (2009). Internal audit: A comfort provider to the audit committee. The British Accounting Review, 41(2), 90–106.

[20] Tricker, B. (2019). Corporate governance: Principles, policies, and practices (4th ed.). Oxford University Press.

How to cite this paper

Serhat Unsal "Power Quality Effects of Renewable Energy Generation on High-Voltage Transmission Lines" Iconic Research And Engineering Journals Volume 8 Issue 9 2025 Page 1998-2007 https://doi.org/10.64388/IREV8I9-1707351
Serhat Unsal "Power Quality Effects of Renewable Energy Generation on High-Voltage Transmission Lines" Iconic Research And Engineering Journals, vol. 8, no. 9, Mar. 2025, doi: https://doi.org/10.64388/IREV8I9-1707351
Serhat Unsal (2025). Power Quality Effects of Renewable Energy Generation on High-Voltage Transmission Lines. Iconic Research And Engineering Journals, 8(9). doi: https://doi.org/10.64388/IREV8I9-1707351
Serhat Unsal "Power Quality Effects of Renewable Energy Generation on High-Voltage Transmission Lines" Iconic Research And Engineering Journals, vol. 8, no. 9, Mar. 2025. Crossref, https://doi.org/10.64388/IREV8I9-1707351
@article{1707351,
      author = {Serhat Unsal},
      title = {Power Quality Effects of Renewable Energy Generation on High-Voltage Transmission Lines},
      journal = {Iconic Research And Engineering Journals},
      year = {2025},
      volume = {8},
      number = {9},
      pages = {1998-2007},
      issn = {2456-8880},
      url = {https://www.irejournals.com/formatedpaper/1707351.pdf},
      abstract = {The integration of renewable energy sources into high-voltage (HV) transmission systems introduces complex power quality challenges due to the widespread use of power electronic converters in wind and solar generation. These converter-dominated units significantly affect harmonic characteristics, interharmonic propagation, voltage stability, and sub-synchronous oscillation behavior. The analysis presented in this study synthesizes the major power quality impacts observed in modern transmission grids with increasing renewable penetration. Results show that harmonic distortion and resonance risks intensify in networks where underground cables, MMC-HVDC links, and large inverter-based resources interact, shifting system impedance and lowering resonance frequencies. Voltage fluctuations and reactive power imbalance caused by large-scale wind integration further degrade stability, particularly in weak grids with low short-circuit strength. Sub-synchronous resonance mechanisms differ between turbine technologies, where DFIG units primarily trigger induction-generator-based SSR, while full-converter turbines exhibit control-interaction-driven SSCI. Mitigation strategies identified as most effective include MMC-HVDC systems, STATCOM and UPFC-based dynamic compensation, Battery Energy Storage Systems (BESS), and grid-forming inverter control. Overall, advanced converter control, coordinated reactive power support, and harmonic-aware transmission planning are essential to ensure secure and reliable operation in high-renewable HV networks.},
      keywords = {Harmonic Distortion, Power Quality, Renewable Energy, Sub-Synchronous Resonance, Transmission Lines},
      month = {March},
      doi = {https://doi.org/10.64388/IREV8I9-1707351}
  }