International Peer-Reviewed Journal•Open Access•ISSN 2456-8880
irejournals@gmail.com•+91-7433024337

Home / Current Issue / Paper 1707843

1707843 Vol 8 · Issue 10 Download Paper

Development of an Automatic Poultry Waste Self-Cleaning System

Ola Ibukun Adekola Sofodun Boluwatife Otegbade Adijat Christiana Amos Adedoyin Titi Ajayi, David Aderemi Oni Samuel Ololade Adebayo Olayanju, T.M.A. Ajisegiri E.S.A.

Subject area: Science,Engineering and Technology  ·  Area of research: Health Management System

Abstract

Management of poultry waste in residential site requires the removal of unwanted odor that could be released to the environment. This could cause severe air pollution and also constitute a great health hazardous treat to occupants of residence. A novel self-cleaning automatic poultry waste cleaner was developed. The unit consists of a 2 X 6 poultry cells battery cage system, 0.1m3 (100l) overhead tank with 25 mm diameter water piping system linking; a tank, 500 W pressure pump and the two waste collectors for flushing waste into waste receptacles. A digital timer (OMIRON DH48S-S/1Z(H5CN)) and contactor switch of 40 Amps, 220 V/3kW were used to activate and deactivate the flushing system at 10 seconds interval. Timely flushing of waste generated a discharge rate of flushed waste into the upper and lower receptacle collectors; at 145 ? 10-6 m3/s and 59 ? 10-6 m3/s. The discharge effluent flow rate power for both upper and lower receptacle collector were 3.63 and 1.47 Watts; indicating power expended within the flushing system to be 372.91 W. The performance of the unit to timely removal of waste was 100% effective; in that no traces of waste were found in the waste collector thereby removing the unwanted odor from environment. However, there is still need to modify the unit by reducing the volume of flushed water waste of 1.64 ? 10-3 m3 (upper) and 0.58 ? 10-3 m3 (lower) receptacles to a feasible volume for further processing into manure water for irrigation or feedstock for a bio-digester. The system is workable and needs improvement for commercial enterprise in poultry ventures to adopt.

Keywords

Automatic, Self-Cleaning System, Flushing, Poultry-Waste, Receptacle

References

[1] Barbosa-Canovas, G. V., Ortega-Rivas, E., Juliano, P. and Yan, H. 2005. Food PowdersPhysical Properties, Processing, and Functionality. New York, NY: Kluwer Academic/Plenum Pub.

[2] Bitzer, C. C., Sims, J. T. 1988. Estimating the availability of nitrogen in poultry manure through laboratory and filed studies. Journal of Environmental Quality 17: 47-54.

[3] Carr, L. E. 1998. Research and Innovative Technology Section. National Poultry Environmental Dialogue, Tucker, GA: U. S. Poultry and Egg Assocation.

[4] Clark, S., Rylander, R. and Larsson, L. 1983. Airborne bacteria, endotoxin and fungi in dust in poultry and swine confinement buildings. Am. Indus, Hygiene Assoc. J., 44(7): 537–541.

[5] Collins, A. R., Murphy, J. and Bainbridge, D. 2000. Optimal Loading Rates and Economic Analyses for Anaerobic Digestion of Poultry Waste. Journal of the Air and Waste Management Association. 50(6): 1037-1044.

[6] Collins, E.R., Jr.; Barker, J.C.; Carr, L.E.; Brodie, H.L.; Martin, J.H., Jr. 1999. Poultry Waste Management Handbook; Natural Resource, Agricultural, and Engineering Service: Ithaca, NY, 1999; 1–64.6. NRAES-132.

[7] FAO. 2006. Livestock’s long shadow. Rome.

[8] FAO. 2008. Poultry in the 21st century: avian influenza and beyond. Proceedings of the International Poultry Conference, Bangkok, 5–7 Nov. 2008, edited by O. Thieme and D. Pilling.

[9] Hills, D. J. and Ravishanker, P. 1984. Methane gas from high solids digestion of poultry manure and wheat straw. Poultry Science 63: 1338-1345.

[10] Mormino, Kathy (30 October 2013). “The Deep Litter Method Of Waste Management In Chicken Coops”. Retrieved 22 February 2017.

[11] Nahm, K.H. & Nahm, B.A. 2004. Poultry production and waste management. Republic of Korea, Yu Han Publishing. ISBN 89-7722-623-6.

[12] Ndegwa, P. M., Thompson, S. A., Merka, W. C. 1991. Fractionation of poultry litter for enhanced utilization. Transactions of the ASAE 34(3): 992-997.

[13] Nicholson, F. A., Chambers, B. J., Smith, K. A. 1996. Nutrient Composition of Poultry Manures in England and Wales. Bioresource Technology 58(3): 279-284.

[14] Poultry farms. Poultry Science Association. 2009. Research demonstrates effectiveness of trees and shrubs in reducing odours, dust and ammonia from Power Production. Biomass and Bioenergy 10(2): 79-92.

[15] Safley, L. M., Vetter, R. L., Smith, L. D. 1987. Management and operation of a full-scale poultry waste digester. Poultry Science 66: 941-945.

[16] Saqib M., 2005. Poultry Production: Manure and Wastewater Management. Encyclopedia of Animal Science, DOI: 10.1081/E-EAS 120023828.

[17] Sweeten, J. M., Annamalai, K., Thien, B., McDonald, L. A. 2003. Co-firing of coal and cattle feedlot biomass (FB) fuels. Part I. Feedlot biomass (cattle manure) fuel quality and characteristics. Fuel 82(10): 1167-1182.

[18] University Of Cenntral Florida (UCF) 2016 Bernoulli’s Equation University Physics Volume-1 UCF Press books OpenStax 2016 htttps://pressbooks.online.ucf.edu.

[19] Date accessed June 30. 2022 Time 3:38pm

[20] Wade, W. McCall. Chicken manure. Reprinted June, 1980-2M. Washington, DC, 1992.

[21] Webb, A. R., Hawkes, F. R. 1985. Laboratory scale anaerobic digestion of poultry litter: gas yieldloading rate relationship. Agricultural Wastes 13: 31-49.

[22] Williams, M., Barker, J. & Sims, J. 1999. Management and utilization of poultry wastes. Rev Environ Contam Toxicol., 162: 105–157.

[23] Woodcock, C. R., Mason, J. S. 1987. Bulk Solids Handling: An Introduction to the Practice and Technology. Glasgow, Scotland: Blackie and Son Ltd.

[24] Woodcock, C. R., Mason, J. S. 1987. Bulk Solids Handling: An Introduction to the Practice and Technology. Glasgow, Scotland: Blackie and Son Ltd.

How to cite this paper

Ola Ibukun Adekola, Sofodun Boluwatife, Otegbade Adijat Christiana; Amos Adedoyin Titi, Ajayi, David Aderemi; Oni Samuel Ololade Adebayo, Olayanju, T.M.A.; Ajisegiri E.S.A. "Development of an Automatic Poultry Waste Self-Cleaning System" Iconic Research And Engineering Journals Volume 8 Issue 10 2025 Page 1226-1233
Ola Ibukun Adekola, Sofodun Boluwatife, Otegbade Adijat Christiana; Amos Adedoyin Titi, Ajayi, David Aderemi; Oni Samuel Ololade Adebayo, Olayanju, T.M.A.; Ajisegiri E.S.A. "Development of an Automatic Poultry Waste Self-Cleaning System" Iconic Research And Engineering Journals, vol. 8, no. 10, Apr. 2025
Ola Ibukun Adekola, Sofodun Boluwatife, Otegbade Adijat Christiana; Amos Adedoyin Titi, Ajayi, David Aderemi; Oni Samuel Ololade Adebayo, Olayanju, T.M.A.; Ajisegiri E.S.A. (2025). Development of an Automatic Poultry Waste Self-Cleaning System. Iconic Research And Engineering Journals, 8(10).
Ola Ibukun Adekola, Sofodun Boluwatife, Otegbade Adijat Christiana; Amos Adedoyin Titi, Ajayi, David Aderemi; Oni Samuel Ololade Adebayo, Olayanju, T.M.A.; Ajisegiri E.S.A. "Development of an Automatic Poultry Waste Self-Cleaning System" Iconic Research And Engineering Journals, vol. 8, no. 10, Apr. 2025.
@article{1707843,
      author = {Ola Ibukun Adekola, Sofodun Boluwatife, Otegbade Adijat Christiana; Amos Adedoyin Titi, Ajayi, David Aderemi; Oni Samuel Ololade Adebayo, Olayanju, T.M.A.; Ajisegiri E.S.A.},
      title = {Development of an Automatic Poultry Waste Self-Cleaning System},
      journal = {Iconic Research And Engineering Journals},
      year = {2025},
      volume = {8},
      number = {10},
      pages = {1226-1233},
      issn = {2456-8880},
      url = {https://www.irejournals.com/formatedpaper/1707843.pdf},
      abstract = {Management of poultry waste in residential site requires the removal of unwanted odor that could be released to the environment. This could cause severe air pollution and also constitute a great health hazardous treat to occupants of residence. A novel self-cleaning automatic poultry waste cleaner was developed. The unit consists of a 2 X 6 poultry cells battery cage system, 0.1m3 (100l) overhead tank with 25 mm diameter water piping system linking; a tank, 500 W pressure pump and the two waste collectors for flushing waste into waste receptacles. A digital timer (OMIRON DH48S-S/1Z(H5CN)) and contactor switch of 40 Amps, 220 V/3kW were used to activate and deactivate the flushing system at 10 seconds interval. Timely flushing of waste generated a discharge rate of flushed waste into the upper and lower receptacle collectors; at 145 ? 10-6 m3/s and 59 ? 10-6 m3/s. The discharge effluent flow rate power for both upper and lower receptacle collector were 3.63 and 1.47 Watts; indicating power expended within the flushing system to be 372.91 W. The performance of the unit to timely removal of waste was 100% effective; in that no traces of waste were found in the waste collector thereby removing the unwanted odor from environment. However, there is still need to modify the unit by reducing the volume of flushed water waste of 1.64 ? 10-3 m3 (upper) and 0.58 ? 10-3 m3 (lower) receptacles to a feasible volume for further processing into manure water for irrigation or feedstock for a bio-digester. The system is workable and needs improvement for commercial enterprise in poultry ventures to adopt.},
      keywords = {Automatic, Self-Cleaning System, Flushing, Poultry-Waste, Receptacle},
      month = {April},
  }