International Peer-Reviewed JournalOpen AccessISSN 2456-8880
irejournals@gmail.com+91-7433024337

Home / Current Issue / Paper 1722355

1722355 Vol 10 · Issue 2 Download Paper

Effects of Natural Ventilation On Users’ Comfort in Administrative Buildings in Southwestern Nigerian Federal Polytechnics

Yekeen Waliu Adetayo Funmilayo Lanrewaju Amao

Subject area: Science,Engineering and Technology  ·  Area of research: Architecture

DOI: 10.64388/IREV10I2-1722355

Abstract

This study assessed the effects of natural ventilation on users’ comfort in selected administrative buildings of Federal Polytechnics in Southwestern Nigeria. A mixed-method research design was adopted across Federal Polytechnic Ede, Federal Polytechnic Ado-Ekiti and Federal Polytechnic Ilaro. Data were obtained through structured questionnaires, physical observation, field measurements and interviews. A total of 295 valid questionnaire responses were analysed alongside qualitative observations. Findings showed that the surveyed buildings were predominantly low- to medium-rise, with cellular office layouts, operable windows and mixed-mode ventilation systems. Natural ventilation was strongly recognised as beneficial, with the statement that natural ventilation improves indoor comfort recording the highest mean score of 3.71, while comfort without mechanical cooling recorded the lowest score of 2.99. Cross ventilation was mostly rated fair, with 40.0% of respondents reporting fair performance, 20.0% poor and 10.2% unavailable. Interview findings further identified thermal discomfort during hot periods, dependence on mechanical cooling and uneven airflow distribution as major concerns. A very strong positive association was observed between ventilation quality and users’ comfort and work performance (r = 0.98), although the relationship was derived from four paired mean observations and should therefore be interpreted cautiously. The study concludes that natural ventilation contributes meaningfully to comfort and workplace performance, but current building configurations do not consistently provide satisfactory conditions. It recommends improved orientation, operable window design, cross-ventilation, shading, airflow pathways and reduced dependence on mechanical cooling in future administrative buildings.

Keywords

natural ventilation, users’ comfort, administrative buildings, federal polytechnics, thermal comfort.

References

[1] Adeyemi, A., & Ogunsemi, D. R. (2020). Climate-responsive features of traditional architecture in southwestern Nigeria. Frontiers of Architectural Research, 9(3), 576–589.

[2] Ajayi, O. A., & Adebayo, A. A. (2017). Thermal comfort and ventilation efficiency in naturally ventilated office buildings in Southwestern Nigeria. Journal of Building Performance, 8(2), 45–58.

[3] Akubue, J. A. (2023). Investigation of airflow for natural ventilation in the typical medium-rise housing cluster in South-Eastern Nigeria. International Journal of Architecture, Arts and Applications, 9(1), 14–19.

[4] Akubue, J. A., & Adesina, D. O. (2023). The effect of courtyard geometry on airflow regimes for ventilation in tropical Nigerian environment. Journal of Architectural Environment and Structural Engineering Research, 6(4).

[5] Alabor, O. Z., Anyanechi, H., & Onyekwere, W. C. (2024). The impact of green building design on indoor air quality and occupant experience: A case study of Heritage Place, Ikoyi, Lagos State. African Journal of Environmental Sciences and Renewable Energy, 16(1), 203–215.

[6] ASHRAE. (2022). ASHRAE Standard 55: Thermal environmental conditions for human occupancy. American Society of Heating, Refrigerating and Air-Conditioning Engineers.

[7] CIBSE. (2021). Environmental design guide. Chartered Institution of Building Services Engineers.

[8] Ho, T. P., Tran, K. B., Nguyen, T. H., & Truong, T. T. (2023). Study on natural ventilation for civil buildings. 5, 43–35.

[9] Irsyad, A., Dewi, O. C., & Rahmasari, K. (2023). Study recommendations to achieve thermal comfort in an educational building. DIMENSI (Journal of Architecture and Built Environment), 50(1), 1–12.

[10] Zaniboni, L., & Albatici, R. (2022). Natural and mechanical ventilation concepts for indoor comfort and well-being with a sustainable design perspective: A systematic review. Buildings, 12(11).

How to cite this paper

Yekeen Waliu Adetayo, Funmilayo Lanrewaju Amao "Effects of Natural Ventilation On Users’ Comfort in Administrative Buildings in Southwestern Nigerian Federal Polytechnics" Iconic Research And Engineering Journals Volume 10 Issue 2 2026 Page 1519-1525 https://doi.org/10.64388/IREV10I2-1722355
Yekeen Waliu Adetayo, Funmilayo Lanrewaju Amao "Effects of Natural Ventilation On Users’ Comfort in Administrative Buildings in Southwestern Nigerian Federal Polytechnics" Iconic Research And Engineering Journals, vol. 10, no. 2, Aug. 2026, doi: https://doi.org/10.64388/IREV10I2-1722355
Yekeen Waliu Adetayo, Funmilayo Lanrewaju Amao (2026). Effects of Natural Ventilation On Users’ Comfort in Administrative Buildings in Southwestern Nigerian Federal Polytechnics. Iconic Research And Engineering Journals, 10(2). doi: https://doi.org/10.64388/IREV10I2-1722355
Yekeen Waliu Adetayo, Funmilayo Lanrewaju Amao "Effects of Natural Ventilation On Users’ Comfort in Administrative Buildings in Southwestern Nigerian Federal Polytechnics" Iconic Research And Engineering Journals, vol. 10, no. 2, Aug. 2026. Crossref, https://doi.org/10.64388/IREV10I2-1722355
@article{1722355,
      author = {Yekeen Waliu Adetayo, Funmilayo Lanrewaju Amao},
      title = {Effects of Natural Ventilation On Users’ Comfort in Administrative Buildings in Southwestern Nigerian Federal Polytechnics},
      journal = {Iconic Research And Engineering Journals},
      year = {2026},
      volume = {10},
      number = {2},
      pages = {1519-1525},
      issn = {2456-8880},
      url = {https://www.irejournals.com/formatedpaper/1722355.pdf},
      abstract = {This study assessed the effects of natural ventilation on users’ comfort in selected administrative buildings of Federal Polytechnics in Southwestern Nigeria. A mixed-method research design was adopted across Federal Polytechnic Ede, Federal Polytechnic Ado-Ekiti and Federal Polytechnic Ilaro. Data were obtained through structured questionnaires, physical observation, field measurements and interviews. A total of 295 valid questionnaire responses were analysed alongside qualitative observations. Findings showed that the surveyed buildings were predominantly low- to medium-rise, with cellular office layouts, operable windows and mixed-mode ventilation systems. Natural ventilation was strongly recognised as beneficial, with the statement that natural ventilation improves indoor comfort recording the highest mean score of 3.71, while comfort without mechanical cooling recorded the lowest score of 2.99. Cross ventilation was mostly rated fair, with 40.0% of respondents reporting fair performance, 20.0% poor and 10.2% unavailable. Interview findings further identified thermal discomfort during hot periods, dependence on mechanical cooling and uneven airflow distribution as major concerns. A very strong positive association was observed between ventilation quality and users’ comfort and work performance (r = 0.98), although the relationship was derived from four paired mean observations and should therefore be interpreted cautiously. The study concludes that natural ventilation contributes meaningfully to comfort and workplace performance, but current building configurations do not consistently provide satisfactory conditions. It recommends improved orientation, operable window design, cross-ventilation, shading, airflow pathways and reduced dependence on mechanical cooling in future administrative buildings.},
      keywords = {natural ventilation, users’ comfort, administrative buildings, federal polytechnics, thermal comfort.},
      month = {August},
      doi = {https://doi.org/10.64388/IREV10I2-1722355}
  }