Abstract
Acoustic comfort in lecture theatres is a critical determinant of speech intelligibility, learning effectiveness, and user satisfaction, yet it remains a frequently overlooked design parameter in many Nigerian tertiary institutions. This study therefore evaluates the design requirements for achieving and acoustic comfort and assessing the facilities at Oke-Ogun Polytechnic, Saki, Nigeria. A mixed-methods approach was employed, combining objective physical audits of eight lecture theatres with subjective assessments from 342 students. Data were collected using structured questionnaires which was analysed with Likert Scale (Mean Weighted Value, MWV) and direct observation. Findings reveal significant acoustic deficiencies. Key design requirements identified include: achieving a reverberation time (RT) suitable for speech (not exceeding 1.0 seconds) by moving away from hard, reflective finishes (terrazzo, plaster, corrugated metal) towards absorptive materials (acoustic tiles, fabric-wrapped panels); implementing a robust building envelope with sound-insulating walls, sealed double-glazed windows, and insulated roofing to mitigate external noise (rain, generators, traffic MWV up to 3.43); adopting fan-shaped or splayed geometries to improve sound distribution and reduce flutter echoes; integrating sound reinforcement systems as a complement to, not a replacement for, good architectural acoustics; and establishing acoustic buffer zones within campus planning. The study concludes that design for acoustic comfort requires a holistic, performance-based strategy, moving beyond a singular focus on durability and capacity. These findings provide an evidence-based framework for designing the proposed Lecture Theatre for the College of Nursing Science, Saki and serve as a reference for similar educational building projects in acoustically challenging tropical contexts.
Keywords
acoustic comfort, lecture theatre design, speech intelligibility, reverberation time, oke-ogun polytechnic, architectural acoustics, nigeria.
References
[1] Adeyemi, T. (2022). The impact of indoor ambient noise on cognitive performance of architecture students. Journal of Built Environment and Technology, 4(1), 45-58.
[2] Akinwale, S., and Ojo, T. (2024). Campus planning and noise control for acoustic comfort in lecture theatre complexes. Nigerian Journal of Urban and Regional Planning, 8(1), 77-92.
[3] Ayinla, A. K., Ekpo, A., Adebisi, O., and Adetunji, T. (2023). Acoustic performance of lecture theatres in a Nigerian university: A post-occupancy evaluation. Journal of Building Performance, 14(2), 112-128.
[4] Eze, C., and Mohammed, I. (2024). Correlation between speech transmission index and academic performance in university lecture theatres. Nigerian Educational Research Journal, 12(2), 101-115.
[5] Obisung, E., Okon, B., and Udoh, E. (2021). Reflective surfaces and acoustic quality in university auditoria. Nigerian Journal of Architectural Research, 3(2), 29-43.
[6] Ogunode, J., and Babalola, O. (2022). Analysis of roofing system impact on acoustic performance of large-span lecture theatres. Journal of Construction and Materials Research, 4(2), 44-59.
[7] Okafor, C., and Bello, A. (2024). Architectural form and acoustic performance of tertiary institution lecture theatres. Journal of Building Performance, 5(1), 112-125.
[8] Okonkwo, V., and Iweka, O. (2021). The influence of lecture theatre geometry on acoustic performance. Nigerian Journal of Architectural Research, 3(2), 29-43.
[9] Oladimeji, A., and Abdulsalam, K. (2022). Reverberation time and speech intelligibility in university learning spaces. African Journal of Environmental Sciences and Technology, 16(3), 89-101.
[10] Sani, M., and Okoro, C. (2022). Assessment of background noise sources in university lecture theatres. Journal of Nigerian Institute of Building, 4(1), 60-75.
[11] Yusuf, F., and Adeyemi, A. (2023). Evaluating the acoustic absorption properties of locally sourced bio-based materials. Journal of Sustainable Materials and Engineering, 6(3), 18-32.
How to cite this paper
@article{1722592,
author = {Goodnews Adepoju Adelodun, Ayinla, Abdulrasaq Kunle, Gbenga Daniel Joshua},
title = {Design Requirements for Acoustic Comfort in Lecture Theatres: A Case Study of Oke-Ogun Polytechnic, Saki, Nigeria},
journal = {Iconic Research And Engineering Journals},
year = {2026},
volume = {10},
number = {2},
pages = {2980-2986},
issn = {2456-8880},
url = {https://www.irejournals.com/formatedpaper/1722592.pdf},
abstract = {Acoustic comfort in lecture theatres is a critical determinant of speech intelligibility, learning effectiveness, and user satisfaction, yet it remains a frequently overlooked design parameter in many Nigerian tertiary institutions. This study therefore evaluates the design requirements for achieving and acoustic comfort and assessing the facilities at Oke-Ogun Polytechnic, Saki, Nigeria. A mixed-methods approach was employed, combining objective physical audits of eight lecture theatres with subjective assessments from 342 students. Data were collected using structured questionnaires which was analysed with Likert Scale (Mean Weighted Value, MWV) and direct observation. Findings reveal significant acoustic deficiencies. Key design requirements identified include: achieving a reverberation time (RT) suitable for speech (not exceeding 1.0 seconds) by moving away from hard, reflective finishes (terrazzo, plaster, corrugated metal) towards absorptive materials (acoustic tiles, fabric-wrapped panels); implementing a robust building envelope with sound-insulating walls, sealed double-glazed windows, and insulated roofing to mitigate external noise (rain, generators, traffic MWV up to 3.43); adopting fan-shaped or splayed geometries to improve sound distribution and reduce flutter echoes; integrating sound reinforcement systems as a complement to, not a replacement for, good architectural acoustics; and establishing acoustic buffer zones within campus planning. The study concludes that design for acoustic comfort requires a holistic, performance-based strategy, moving beyond a singular focus on durability and capacity. These findings provide an evidence-based framework for designing the proposed Lecture Theatre for the College of Nursing Science, Saki and serve as a reference for similar educational building projects in acoustically challenging tropical contexts.},
keywords = {acoustic comfort, lecture theatre design, speech intelligibility, reverberation time, oke-ogun polytechnic, architectural acoustics, nigeria.},
month = {August},
doi = {https://doi.org/10.64388/IREV10I2-1722592}
}