International Peer-Reviewed Journal•Open Access•ISSN 2456-8880
[email protected]•+91-7433024337

Home / Current Issue / Paper 1724728

1724728 Vol 10 · Issue 5 Download Paper

Microbiological Quality of Air at Different Sections Within Spiritan University, Nneochi, Abia State

Okereke, F.O Iheanacho, G.C Opara-Nadi, N Ofordi, O.A Iche, I Unaegbu, V. N Ogwuegbu, H.O Ekechukwu, C. C Enweonye, O. N Nwankwo, T

Subject area: Biological & Medical Sciences  ·  Area of research: Microbiology

Abstract

Airborne diseases have been described among debilitating ailments that are ravaging the health of mankind, especially individuals whose immune functions are deficient. Screening for the quality of air at different areas that humans frequently visit has been described as essential to achieving global health goals. This study was carried out to evaluate the microbiological quality of air at different confined environments at Spiritan University, Nneochi, Abia State. Microbial quality of air at different sections at the University was evaluated using passive method. Three prepared Petri dishes containing different selective media were exposed for 60 min at 10 selected areas. The microbial isolates were characterized based on their cultural, morphological, and biochemical features while fungal atlas facilitated fungal identification. The outcome of the air sampling revealed the presence of Pseudomonas aeruginosa (6, 25.00%), Staphylococcus aureus (4, 16.67%), Escherichia coli (3, 12.50%), Streptococcus pneumoniae (3, 12.50%), Aspergillus fumigatus (5, 20.83%), and Aspergillus niger (3, 12.50%). The highest microbial load was observed at the University Clinic (83.33 CFU/m3 for bacteria/4.17 CFU/m3 for fungi) while the least was observed at the Senate Chamber and Canteen (25.00 CFU/m3 for bacteria/2.50 CFU/m3 for fungi). The microbial load in all the sections sampled was within small and medium as stipulated by the European Community Commission (ECC). This study has shown that different bacteria and fungi are found at different sections within Spiritan University, Nneochi, though the microbial load does not pose a threat to the inhabitants. Moreover, more research is needed in order to evaluate the pathogenic potential and susceptibility pattern of the bacterial and fungal isolates.

Keywords

Air quality; Air sampling; Microorganisms; Spiritan University

References

[1] Alfanda AM, Mas’ud M, Mas’ud F (2023). Assessment of the microbial quality of air in some science laboratories of Bayero University Kano Old Campus, Nigeria. Journal of Pollution Effects & Control, 11, 78–388.

[2] Amengialue OO, Igbinosa IH, Igbinosa EO (2017a). Microbiological quality assessment of indoor air of a private university in Benin City, Nigeria. IOSR Journal of Pharmacy and Biological Sciences, 12(3), 19–25.

[3] Amengialue OO, Omoigberale MN, Okwu GI (2017b). Microbial assessment of indoor air quality in a private university in Benin City, Nigeria. Journal of Applied Sciences and Environmental Management, 21(4), 735–741.

[4] Asif A, Zeeshan M, Hashmi I, Zahid U, Bhatti MF (2018). Microbial quality assessment of indoor air in a large hospital building during winter and spring seasons. Building and Environment, 135, 68–73. https://doi.org/10.1016/j.buildenv.2018.03.010

[5] Awad AH, Saeed Y, Hassan Y, Fawzy Y, Osman M (2018). Air microbial quality in certain public buildings, Egypt: A comparative study. Atmospheric Pollution Research, 9(4), 617–626. https://doi.org/10.1016/j.apr.2017.12.014

[6] Awosika SA, Olajubu FA, Amusa NA (2012). Microbiological assessment of indoor air of a teaching hospital in Nigeria. Asian Pacific Journal of Tropical Biomedicine, 2(6), 465–468. https://doi.org/10.1016/S2221-1691(12)60077-X

[7] Cheesbrough M (2010). District laboratory practice in tropical countries, 2nd ed. Cambridge University Press, Cambridge.

[8] Department of Occupational Safety and Health (2010). Industrial code of practice on indoor air quality. Ministry of Human Resources, Malaysia.

[9] Kim SY, Jheong W, Hwang ES, Kim JH, Jung JS, Lee JW, Chung HM, Kwon M (2016). Airborne bacteria concentration and species identification in residential living spaces. Journal of Environmental Health Sciences, 42(6), 438–449. https://doi.org/10.5668/JEHS.2016.42.6.438

[10] Oke IA, Adeyemi AT, Oladipo OA (2020). Comparative analysis of indoor and outdoor air quality in Ogbomoso, Nigeria. Journal of Environmental Protection, 11(9), 711–725.

[11] Okunola OJ, Adekola OF, Adewuyi GO (2020). Indoor air quality assessment in selected residential buildings in Lagos, Nigeria. Journal of Environmental Health Research, 18(2), 78–85.

[12] Oluwafemi F, Adebayo AA, Adesina BT (2021). Airborne microbial contamination in poultry and livestock production facilities in Nigeria. Nigerian Veterinary Journal, 42(3), 189–198.

[13] Ugranli T, Gungormus E, Sofuoglu A, Sofuoglu SC (2016). Indoor air quality in chemical laboratories. Comprehensive Analytical Chemistry, 73, 859–878. https://doi.org/10.1016/bs.coac.2016.02.017

[14] Yau YH, Chew BT, Saifullah AZA (2012). Studies on the indoor air quality of pharmaceutical laboratories in Malaysia. International Journal of Sustainable Built Environment, 1(1), 110–124. https://doi.org/10.1016/j.ijsbe.2012.07.005

How to cite this paper

Okereke, F.O, Iheanacho, G.C; Opara-Nadi, N, Ofordi, O.A; Iche, I, Unaegbu, V. N; Ogwuegbu, H.O, Ekechukwu, C. C; Enweonye, O. N; Nwankwo, T "Microbiological Quality of Air at Different Sections Within Spiritan University, Nneochi, Abia State" Iconic Research And Engineering Journals Volume 10 Issue 5 2026 Page 918-926
Okereke, F.O, Iheanacho, G.C; Opara-Nadi, N, Ofordi, O.A; Iche, I, Unaegbu, V. N; Ogwuegbu, H.O, Ekechukwu, C. C; Enweonye, O. N; Nwankwo, T "Microbiological Quality of Air at Different Sections Within Spiritan University, Nneochi, Abia State" Iconic Research And Engineering Journals, vol. 10, no. 5, Nov. 2026
Okereke, F.O, Iheanacho, G.C; Opara-Nadi, N, Ofordi, O.A; Iche, I, Unaegbu, V. N; Ogwuegbu, H.O, Ekechukwu, C. C; Enweonye, O. N; Nwankwo, T (2026). Microbiological Quality of Air at Different Sections Within Spiritan University, Nneochi, Abia State. Iconic Research And Engineering Journals, 10(5).
Okereke, F.O, Iheanacho, G.C; Opara-Nadi, N, Ofordi, O.A; Iche, I, Unaegbu, V. N; Ogwuegbu, H.O, Ekechukwu, C. C; Enweonye, O. N; Nwankwo, T "Microbiological Quality of Air at Different Sections Within Spiritan University, Nneochi, Abia State" Iconic Research And Engineering Journals, vol. 10, no. 5, Nov. 2026.
@article{1724728,
      author = {Okereke, F.O, Iheanacho, G.C; Opara-Nadi, N, Ofordi, O.A; Iche, I, Unaegbu, V. N; Ogwuegbu, H.O, Ekechukwu, C. C; Enweonye, O. N; Nwankwo, T},
      title = {Microbiological Quality of Air at Different Sections Within Spiritan University, Nneochi, Abia State},
      journal = {Iconic Research And Engineering Journals},
      year = {2026},
      volume = {10},
      number = {5},
      pages = {918-926},
      issn = {2456-8880},
      url = {https://www.irejournals.com/formatedpaper/1724728.pdf},
      abstract = {Airborne diseases have been described among debilitating ailments that are ravaging the health of mankind, especially individuals whose immune functions are deficient. Screening for the quality of air at different areas that humans frequently visit has been described as essential to achieving global health goals. This study was carried out to evaluate the microbiological quality of air at different confined environments at Spiritan University, Nneochi, Abia State. Microbial quality of air at different sections at the University was evaluated using passive method. Three prepared Petri dishes containing different selective media were exposed for 60 min at 10 selected areas. The microbial isolates were characterized based on their cultural, morphological, and biochemical features while fungal atlas facilitated fungal identification. The outcome of the air sampling revealed the presence of Pseudomonas aeruginosa (6, 25.00%), Staphylococcus aureus (4, 16.67%), Escherichia coli (3, 12.50%), Streptococcus pneumoniae (3, 12.50%), Aspergillus fumigatus (5, 20.83%), and Aspergillus niger (3, 12.50%). The highest microbial load was observed at the University Clinic (83.33 CFU/m3 for bacteria/4.17 CFU/m3 for fungi) while the least was observed at the Senate Chamber and Canteen (25.00 CFU/m3 for bacteria/2.50 CFU/m3 for fungi). The microbial load in all the sections sampled was within small and medium as stipulated by the European Community Commission (ECC). This study has shown that different bacteria and fungi are found at different sections within Spiritan University, Nneochi, though the microbial load does not pose a threat to the inhabitants. Moreover, more research is needed in order to evaluate the pathogenic potential and susceptibility pattern of the bacterial and fungal isolates.},
      keywords = {Air quality; Air sampling; Microorganisms; Spiritan University},
      month = {November},
  }