Home / Current Issue / Paper 1725165
IoT Based Supervisory Control and Data Acquisition for Solar Microgrid Operation in Bonny Island
Subject area: Science,Engineering and Technology · Area of research: Electrical Engineering
Abstract
An IoT-enabled SCADA system was designed and tested for real-time supervisory monitoring of a PV-battery microgrid. The study considered the issues of limited visibility of renewable generation and battery conditions, electrical loading, voltage and frequency excursions, IoT delay, and slow detection of abnormal operating conditions in small-scaled microgrids. An IoT-enabled data acquisition system architecture was implemented to measure solar irradiance, PV voltage, current and power, load power, battery SOC, bus voltage and frequency; followed by implementation of an IoT-enabled supervisory platform for: graphical visualization of the electrical variables, generation of alarms when the measured variables were above or below their thresholds, and commands for supervisory control. Mathematical models were further derived for: PV generation, battery SOC, three-phase power, alarm activation, the effect of communication delays, supervisory control, monitoring accuracy, and system availability. The system was validated using ten samples collected from 08:00 to 12:30 hours. Results showed PV power generation increased from 2.48 kW at 08:00 hours to a maximum 7.60 kW at 11:30 hours when solar irradiance increased from 285 to 820 W/m². Load demand increased from 3.10 to 7.15 kW resulting in a power deficit at 08:00 hours of 0.62 kW, a power surplus of 2.05 kW at 11:30 hours, and 0.75 kW at 12:30 hours of power deficit. Battery SOC increased from 72.4 to 80.1%. Delay in communication time fluctuated between 59 to 118 ms with an average value of 74.4 ms. The bus voltage decreased to 397.4 V and frequency to 49.87 Hz at 12:30 hours before the SCADA alarm was activated. These results highlight the effectiveness of an IoT-SCADA integrated system for telemonitoring, remote supervision and control of renewables microgrids. The study guides policies for IoT communication standardization, metering calibration, minimum cybersecurity, necessary interoperability, data availability, and supervisory monitoring standard requirements for renewables microgrids.
Keywords
Internet of Things (IoT), SCADA, solar PV microgrid, battery energy storage, supervisory monitoring
How to cite this paper
@article{1725165,
author = {Richard Zarapege, H. N. Amadi},
title = {IoT Based Supervisory Control and Data Acquisition for Solar Microgrid Operation in Bonny Island},
journal = {Iconic Research And Engineering Journals},
year = {2026},
volume = {10},
number = {5},
pages = {2903-2915},
issn = {2456-8880},
url = {https://www.irejournals.com/formatedpaper/1725165.pdf},
abstract = {An IoT-enabled SCADA system was designed and tested for real-time supervisory monitoring of a PV-battery microgrid. The study considered the issues of limited visibility of renewable generation and battery conditions, electrical loading, voltage and frequency excursions, IoT delay, and slow detection of abnormal operating conditions in small-scaled microgrids. An IoT-enabled data acquisition system architecture was implemented to measure solar irradiance, PV voltage, current and power, load power, battery SOC, bus voltage and frequency; followed by implementation of an IoT-enabled supervisory platform for: graphical visualization of the electrical variables, generation of alarms when the measured variables were above or below their thresholds, and commands for supervisory control. Mathematical models were further derived for: PV generation, battery SOC, three-phase power, alarm activation, the effect of communication delays, supervisory control, monitoring accuracy, and system availability. The system was validated using ten samples collected from 08:00 to 12:30 hours. Results showed PV power generation increased from 2.48 kW at 08:00 hours to a maximum 7.60 kW at 11:30 hours when solar irradiance increased from 285 to 820 W/m². Load demand increased from 3.10 to 7.15 kW resulting in a power deficit at 08:00 hours of 0.62 kW, a power surplus of 2.05 kW at 11:30 hours, and 0.75 kW at 12:30 hours of power deficit. Battery SOC increased from 72.4 to 80.1%. Delay in communication time fluctuated between 59 to 118 ms with an average value of 74.4 ms. The bus voltage decreased to 397.4 V and frequency to 49.87 Hz at 12:30 hours before the SCADA alarm was activated. These results highlight the effectiveness of an IoT-SCADA integrated system for telemonitoring, remote supervision and control of renewables microgrids. The study guides policies for IoT communication standardization, metering calibration, minimum cybersecurity, necessary interoperability, data availability, and supervisory monitoring standard requirements for renewables microgrids.},
keywords = {Internet of Things (IoT), SCADA, solar PV microgrid, battery energy storage, supervisory monitoring},
month = {November},
}