International Peer-Reviewed Journal•Open Access•ISSN 2456-8880
[email protected]•+91-7433024337

Home / Current Issue / Paper 1725217

1725217 Vol 10 · Issue 5 Download Paper

Risk-Aware Adaptive Image Transmission for Reliable Skin Lesion Screening in Low Bandwidth Settings

Pranjal Jha Vishesh Panghal

Subject area: Science,Engineering and Technology  ·  Area of research: AI & Medical Image Processing

Abstract

Transmitting high-resolution images may cause long delays in bandwidth-limited tele-dermatology, whereas uniform lossy compression may cause small malignant lesions to be missed. This work explores a risk-aware two-stage adaptive transmission heuristic for skin lesion screening. An aggressively compressed image (Q = 30) is first sent from the edge client; if a composite of referral risk and predictive entropy exceeds an empirically derived threshold, a high-quality image (Q = 90) is requested from the edge buffer. On the leakage-free DermaMNIST-C benchmark (28 × 28), the adaptive strategy achieves a referral sensitivity of 96.0% (143/149), within 0.7 percentage points of continuous Q = 90 transmission (144/149), while reducing entropy-coded scan data by 30.8%. A separate model at native resolution (600 × 450) estimates a 57.9% reduction in average payload (24.6 KB vs. 58.4 KB); diagnostic performance on native images was not evaluated. The adaptive strategy achieved a specificity of 99.0% for routine cases, a precision of 92.9% for referred cases and a melanoma recall of 98.6% (69/70), and only one test case bypassed retransmission (0.7%; 95% CI: 0.02%–3.68%). These results show that risk- and entropy-based triage heuristics, combined with failure auditing, can be beneficial in bandwidth-limited tele-screening.

Keywords

Tele-dermatology, adaptive transmission, image compression, rate-distortion, uncertainty estimation, low-bandwidth networks, DermaMNIST-C

References

[1] Tschandl P, Rosendahl C, Kittler H. The HAM10000 dataset, a large collection of multi-source dermatoscopic images of common pigmented skin lesions. Scientific Data. 2018;5(1):1–.

[2] Esteva A, Kuprel B, Novoa RA, Ko J, Swetter SM, Blau HM, et al. Dermatologist-level classification of skin cancer with deep neural networks. Nature. 2017;542(7639):115–.

[3] dos Santos E, Cunha K, Mota R, Papais F, Bezerra T, Lopes N, et al. Bridging research and practice: A systematic evaluation of generalist and dermatology specific models in clinical skin lesion classification. arXiv preprint arXiv:2610.03193. 2026.

[4] Fan FX, Tan C, Ong YS, Wattenhofer R. Authority preserving evaluation of medical vision-language assistants. arXiv preprint arXiv:2609.22302. 2026.

[5] Shahriar MM, Mridha MF. LENS-GRF: Permutation-invariant lesion evidence network with gated residual fusion for acne severity grading and multi-rater clinical oracle analysis. arXiv preprint arXiv:2610.00294. 2026.

[6] Pal A, Patidar G, Santra B. FedDermaSeg: Federated learning for dermatological image segmentation. arXiv preprint arXiv:2610.08574. 2026.

[7] Barua A, Khan MMA, Iktidar A, Islam MS. Masked privileged-information distillation for multimodal skin lesion classification under missing clinical metadata. arXiv preprint arXiv:2610.03991. 2026.

[8] Alvarez D, Thorne S, Gupta R. Progressive image streaming for bandwidth-constrained edge healthcare AI. IEEE Internet of Things Journal. 2024;11(4):5890–5901.

[9] Bause O, Werner J, Bringmann O. CapsuleMotion: A lightweight real-time visual motion predictor for capsule endoscopy. arXiv preprint arXiv:2609.15367. 2026.

[10] Sirjani MS. Hardware-aware functional Kolmogorov–Arnold networks for efficient medical image enhancement and segmentation. arXiv preprint arXiv:2609.36134. 2026.

[11] Wallace GK. The JPEG still picture compression standard. IEEE Transactions on Consumer Electronics. 1992;38(1):xviii–xxxiv.

[12] Bai Y, Zhao Y, Wang K, Du Y, Cheng J, Fang T, et al. Practical lossless volumetric medical image compression via triplane context tree learning. arXiv preprint arXiv:2608.13897. 2026.

[13] Chou HH, Maly J, Rauhut H. Compressive sensing – introduction and relations to deep learning. arXiv preprint arXiv:2608.24211. 2026.

[14] Gorski N, Liang X, Guo H, Wang B. FeatureZ: A general framework for feature-preserving compression via pointwise bounds and star classification. arXiv preprint arXiv:2610.12371. 2026.

[15] Li Y, Bedros S, Bigliardi P, Qi MB, Morellas V, Papanikolopoulos N. MDSkin-Net: Multi-task skin lesion analysis driven by pattern analysis priors and spatial alignment regularization. arXiv preprint arXiv:2609.30855. 2026.

[16] Attia Y, Mukherjee D. CAMEO: A class-activation-mapped equitable overlay framework for fair and robust deep learning-based skin condition diagnosis. arXiv preprint arXiv:2609.36400. 2026.

[17] Yang J, Shi R, Wei D, Liu Z, Zhao L, Ke B, et al. MedMNIST v2: A large-scale lightweight benchmark for 2D and 3D biomedical image classification. Scientific Data. 2023;10(1):41.

[18] Abhishek K, Jain A, Hamarneh G. Investigating the quality of DermaMNIST and Fitzpatrick17k dermatological image datasets. Scientific Data. 2025;12:1–14.

[19] Vu TV, Hai NC, Nguyen NP, Tu NH, Bao VNQ, Anh NT. Less is more: A leakage-controlled study of dermoscopic preprocessing for joint skin lesion classification and segmentation with YOLO26. arXiv preprint arXiv:2610.08570. 2026.

[20] Shannon CE. A mathematical theory of communication. The Bell System Technical Journal. 1948;27(3):379–423.

[21] Zhang J, Li Y, Han L, Anaissi A, Tran NH. Rethinking the information bottleneck: Structured decomposition under label-induced partitions. arXiv preprint arXiv:2610.01175. 2026.

[22] Liu D, Zhu G, Zhang J, Huang K. Wireless data acquisition for edge learning: Data-importance aware retransmission. IEEE Transactions on Wireless Communications. 2020;19(1):406–420.

[23] Geifman Y, El-Yaniv R. Selective classification for deep neural networks. In: Advances in Neural Information Processing Systems (NeurIPS). 2017. p. 4878–4887.

[24] Guo C, Pleiss G, Sun Y, Weinberger KQ. On calibration of modern neural networks. In: International Conference on Machine Learning (ICML). PMLR. 2017. p. 1321–1330.

[25] He K, Zhang X, Ren S, Sun J. Deep residual learning for image recognition. In: Proceedings of the IEEE Conference on Computer Vision and Pattern Recognition (CVPR). 2016. p. 770–778.

[26] Rangnekar A, Tapias Gomez J, Deasy JO, Veeraraghavan H. Parameter-efficient pretrained-CT-to-MRI transfer for rectal cancer segmentation: Performance-calibration trade-offs. arXiv preprint arXiv:2608.27178. 2026.

How to cite this paper

Pranjal Jha, Vishesh Panghal "Risk-Aware Adaptive Image Transmission for Reliable Skin Lesion Screening in Low Bandwidth Settings" Iconic Research And Engineering Journals Volume 10 Issue 5 2026 Page 2974-2984
Pranjal Jha, Vishesh Panghal "Risk-Aware Adaptive Image Transmission for Reliable Skin Lesion Screening in Low Bandwidth Settings" Iconic Research And Engineering Journals, vol. 10, no. 5, Nov. 2026
Pranjal Jha, Vishesh Panghal (2026). Risk-Aware Adaptive Image Transmission for Reliable Skin Lesion Screening in Low Bandwidth Settings. Iconic Research And Engineering Journals, 10(5).
Pranjal Jha, Vishesh Panghal "Risk-Aware Adaptive Image Transmission for Reliable Skin Lesion Screening in Low Bandwidth Settings" Iconic Research And Engineering Journals, vol. 10, no. 5, Nov. 2026.
@article{1725217,
      author = {Pranjal Jha, Vishesh Panghal},
      title = {Risk-Aware Adaptive Image Transmission for Reliable Skin  Lesion Screening in Low Bandwidth Settings},
      journal = {Iconic Research And Engineering Journals},
      year = {2026},
      volume = {10},
      number = {5},
      pages = {2974-2984},
      issn = {2456-8880},
      url = {https://www.irejournals.com/formatedpaper/1725217.pdf},
      abstract = {Transmitting high-resolution images may cause long delays in bandwidth-limited tele-dermatology, whereas uniform lossy compression may cause small malignant lesions to be missed. This work explores a risk-aware two-stage adaptive transmission heuristic for skin lesion screening. An aggressively compressed image (Q = 30) is first sent from the edge client; if a composite of referral risk and predictive entropy exceeds an empirically derived threshold, a high-quality image (Q = 90) is requested from the edge buffer. On the leakage-free DermaMNIST-C benchmark (28 × 28), the adaptive strategy achieves a referral sensitivity of 96.0% (143/149), within 0.7 percentage points of continuous Q = 90 transmission (144/149), while reducing entropy-coded scan data by 30.8%. A separate model at native resolution (600 × 450) estimates a 57.9% reduction in average payload (24.6 KB vs. 58.4 KB); diagnostic performance on native images was not evaluated. The adaptive strategy achieved a specificity of 99.0% for routine cases, a precision of 92.9% for referred cases and a melanoma recall of 98.6% (69/70), and only one test case bypassed retransmission (0.7%; 95% CI: 0.02%–3.68%). These results show that risk- and entropy-based triage heuristics, combined with failure auditing, can be beneficial in bandwidth-limited tele-screening.},
      keywords = {Tele-dermatology, adaptive transmission, image compression, rate-distortion, uncertainty estimation, low-bandwidth networks, DermaMNIST-C},
      month = {November},
  }