Home / Current Issue / Paper 1725222
An Integrated LoRa Fog and Digital Twin Framework for Predictive Maintenance of Telecommunication Shelters
Subject area: Science,Engineering and Technology · Area of research: LoRa, Digital Twin, Machine Learning, CNN-LSTM
Abstract
Telecommunication shelters depend on environmental control and backup power to protect network equipment, yet fixed-threshold monitoring often identifies faults only after conditions have deteriorated. This paper presents a simulation-based predictive-maintenance framework that combines LoRa telemetry, fog-level analytics, a synchronized digital twin, and a convolutional neural network–long short-term memory (CNN–LSTM) model. The simulated shelter produced multivariate temperature, humidity, power, cooling, battery, and grid-state telemetry at five-minute intervals over a nine-day horizon. Controlled scenarios represented cooling degradation and failure, door opening, load increase, and grid outage. A LoRa link model introduced packet loss and delay; fog processing smoothed signals, reconstructed missing timestamps, and generated local anomaly alerts. The digital twin tracked thermal, humidity, and power states, while a multi-task CNN–LSTM classified health states and estimated remaining useful life (RUL). Under the reported configuration, mean LoRa packet success was 86.3% and mean latency was 238 ms. Fog processing reduced temperature-signal variance by 41.6%, reconstructed 92.1% of missing timestamps, and achieved anomaly-detection precision, recall, and F1-score of 0.91, 0.87, and 0.89. Digital-twin tracking errors were 0.78 °C for temperature and 3.1% relative humidity for humidity. The CNN–LSTM achieved 0.94 accuracy and an RUL RMSE of 2.6 hours on the simulated evaluation data. Fog inference averaged 184 ms compared with 612 ms for the cloud-only comparison. These results indicate the potential of an integrated edge and digital-twin approach for shelter monitoring. Since the data and fault labels were simulation-generated, field validation remains necessary before operational use.
Keywords
CNN–LSTM, digital twin, fog computing, LoRa, predictive maintenance, remaining useful life, telecommunication shelter
References
[1] Raza U, Kulkarni P, Sooriyabandara M. Low power wide area networks: an overview. IEEE Communications Surveys & Tutorials. 2017;19(2):855–873. https://doi.org/10.1109/COMST.2017.2652320
[2] Chiang M, Zhang T. Fog and IoT: an overview of research opportunities. IEEE Internet of Things Journal. 2016;3(6):854–864. https://doi.org/10.1109/JIOT.2016.2584538
[3] Hosamo HH, Nielsen HK, Alnmr AN, Svennevig PR, Svidt K. A review of the digital twin technology for fault detection in buildings. Frontiers in Built Environment. 2022;8:1013196. https://doi.org/10.3389/fbuil.2022.1013196
[4] van Dinter R, Tekinerdogan B, Catal C. Predictive maintenance using digital twins: a systematic literature review. Information and Software Technology. 2022;151:107008. https://doi.org/10.1016/j.infsof.2022.107008
[5] Wahid A, Breslin JG, Ali MI. Prediction of machine failure in Industry 4.0: a hybrid CNN-LSTM framework. Applied Sciences. 2022;12(9):4221. https://doi.org/10.3390/app12094221
How to cite this paper
@article{1725222,
author = {Gabriel Chibuoso Okpara, Nwazor Nkolika},
title = {An Integrated LoRa Fog and Digital Twin Framework for Predictive Maintenance of Telecommunication Shelters},
journal = {Iconic Research And Engineering Journals},
year = {2026},
volume = {10},
number = {5},
pages = {3387-3393},
issn = {2456-8880},
url = {https://www.irejournals.com/formatedpaper/1725222.pdf},
abstract = {Telecommunication shelters depend on environmental control and backup power to protect network equipment, yet fixed-threshold monitoring often identifies faults only after conditions have deteriorated. This paper presents a simulation-based predictive-maintenance framework that combines LoRa telemetry, fog-level analytics, a synchronized digital twin, and a convolutional neural network–long short-term memory (CNN–LSTM) model. The simulated shelter produced multivariate temperature, humidity, power, cooling, battery, and grid-state telemetry at five-minute intervals over a nine-day horizon. Controlled scenarios represented cooling degradation and failure, door opening, load increase, and grid outage. A LoRa link model introduced packet loss and delay; fog processing smoothed signals, reconstructed missing timestamps, and generated local anomaly alerts. The digital twin tracked thermal, humidity, and power states, while a multi-task CNN–LSTM classified health states and estimated remaining useful life (RUL). Under the reported configuration, mean LoRa packet success was 86.3% and mean latency was 238 ms. Fog processing reduced temperature-signal variance by 41.6%, reconstructed 92.1% of missing timestamps, and achieved anomaly-detection precision, recall, and F1-score of 0.91, 0.87, and 0.89. Digital-twin tracking errors were 0.78 °C for temperature and 3.1% relative humidity for humidity. The CNN–LSTM achieved 0.94 accuracy and an RUL RMSE of 2.6 hours on the simulated evaluation data. Fog inference averaged 184 ms compared with 612 ms for the cloud-only comparison. These results indicate the potential of an integrated edge and digital-twin approach for shelter monitoring. Since the data and fault labels were simulation-generated, field validation remains necessary before operational use.},
keywords = {CNN–LSTM, digital twin, fog computing, LoRa, predictive maintenance, remaining useful life, telecommunication shelter},
month = {November},
}