Home / Current Issue / Paper 1725287
Design and Implementation of an Edge Computing-Based Smart Energy Meter for Real Time Energy Monitoring and Management
Subject area: Science,Engineering and Technology · Area of research: Embedded Systems
Abstract
Non-intrusive load monitoring infers the activity of individual appliances from a single measurement at the point of supply, avoiding the cost of instrumenting each device. The deep-learning approaches that dominate recent work place inference on a server, leaving the meter dependent on a network link. This paper reports a self-contained instrument in which inference runs on the meter itself. Galvanically isolated sensors are sampled against an analogue reference the device measures at every power-up, and six electrical quantities per acquisition frame are passed to a depth-three decision tree compiled into firmware, which identifies the connected load combination without any network connection. Validating across separate power cycles, rather than by randomly partitioning a single recording, proved decisive: it revealed that reactive power carried predictive value originating in converter offset rather than in the load, and discarding that feature raised accuracy on held-out sessions from 72% to 100% across four load states captured in eight independent acquisitions. Random partitioning conceals this failure entirely. Identified combinations are further decomposed into per-appliance power from learned resistances, agreeing with rated values to within 2.7%, and a shortfall exceeding 7% in combined resistance raises an over-draw alert. At this scale the limiting factor is therefore validation discipline rather than model capacity.
Keywords
Decision trees, edge computing, energy disaggregation, load monitoring, machine learning, microcontrollers
References
[1] Antonopoulos A, et al. ML in power consumption analysis. Energy Informatics. 2020.
[2] Himeur Y, Ghanem K, Alsalemi A, Bensaali F, Amira A. Artificial intelligence based anomaly detection of energy consumption in buildings: A review, current trends and new perspectives. Appl Energy. 2021;287:116601. https://doi.org/10.1016/j.apenergy.2021.116601
[3] Wang X, et al. Smart meter data analytics. IEEE; 2022.
[4] Gopinath R, Kumar M. DeepEdge-NILM: A case study of non-intrusive load monitoring edge device in commercial building. Energy Build. 2023;294:113226. https://doi.org/10.1016/j.enbuild.2023.113226
[5] Wang X, Wang H, Bhandari B, Cheng L. AI-empowered methods for smart energy consumption: A review of load forecasting, anomaly detection and demand response. Int J Precis Eng Manuf-Green Technol. 2024;11(3):963–993. https://doi.org/10.1007/s40684-023-00537-0
[6] Hart GW. Nonintrusive appliance load monitoring. Proc IEEE. 1992;80(12):1870–1891. https://doi.org/10.1109/5.192069
[7] Batra S, Singh M, Kumar H. Smart energy metering system using IoT and machine learning techniques. IEEE Access. 2021;9:112345–112356.
[8] Zeifman M, Roth K. Nonintrusive appliance load monitoring: Review and outlook. IEEE Trans Consum Electron. 2011;57(1):76–84. https://doi.org/10.1109/TCE.2011.5735484
[9] Monisha M, et al. Generative artificial intelligence enabled smart metering framework for predictive energy sharing. IEEE Conference/Journal; 2025.
[10] Latif RMA, et al. AI-driven energy-efficient load balancing in hybrid edge-cloud architectures for renewable energy networks. IEEE Netw Lett. 2026.
[11] Serna D, Morales A, Rodriguez J. NILM on edge devices for smart energy monitoring. Energies. 2025;18(3):1–15.
How to cite this paper
@article{1725287,
author = {Sharon Priya S, Sahana N, Varshitha G G, T S Ananya, Lavanya G},
title = {Design and Implementation of an Edge Computing-Based Smart Energy Meter for Real Time Energy Monitoring and Management},
journal = {Iconic Research And Engineering Journals},
year = {2026},
volume = {10},
number = {5},
pages = {3522-3536},
issn = {2456-8880},
url = {https://www.irejournals.com/formatedpaper/1725287.pdf},
abstract = {Non-intrusive load monitoring infers the activity of individual appliances from a single measurement at the point of supply, avoiding the cost of instrumenting each device. The deep-learning approaches that dominate recent work place inference on a server, leaving the meter dependent on a network link. This paper reports a self-contained instrument in which inference runs on the meter itself. Galvanically isolated sensors are sampled against an analogue reference the device measures at every power-up, and six electrical quantities per acquisition frame are passed to a depth-three decision tree compiled into firmware, which identifies the connected load combination without any network connection. Validating across separate power cycles, rather than by randomly partitioning a single recording, proved decisive: it revealed that reactive power carried predictive value originating in converter offset rather than in the load, and discarding that feature raised accuracy on held-out sessions from 72% to 100% across four load states captured in eight independent acquisitions. Random partitioning conceals this failure entirely. Identified combinations are further decomposed into per-appliance power from learned resistances, agreeing with rated values to within 2.7%, and a shortfall exceeding 7% in combined resistance raises an over-draw alert. At this scale the limiting factor is therefore validation discipline rather than model capacity.},
keywords = {Decision trees, edge computing, energy disaggregation, load monitoring, machine learning, microcontrollers},
month = {November},
}