Abstract
The cyclotron is an advanced particle accelerator that is mostly used to produce short-lived radionuclides or radioisotopes like 18F, 13N, and 11C for Positron Emission Tomography (PET). A cyclotron accelerator produced a well-defined, high-energy, and intensely charged particle beam (Livingston, 1954) with radionuclides produced when this beam hits the object. The aim of this research is to conduct a thorough radiological surveillance of the cyclotron building at the African Medical Center of Excellence (AMCE) in Abuja, Nigeria. A calibrated Ranger Radiation Alert meter was used at twenty-nine (29) survey locations across the facility to conduct a radiation and contamination survey. The results obtained show that the least radiation levels were obtained at synthesizer, emergency and exit main entrance with values of 0.01 μSv/h, 0.02 μSv/h and 0.03 μSv/h respectively. While highest radiation levels were obtained at T3 and T7 with values of 5.39 μSv/h and 5.89 μSv/h respectively. Although, these values are high but do not exceed limit of 7.5 μSv/h in the controlled area (Cyclotron Vault and Hot Lab) prescribed in Nigeria Basic Ionising Radiation Regulations of 2025. The study concluded that there was no indication of contamination in all the areas surveyed and recommended that regular radiation monitoring should be carried out periodically.
Keywords
radiation, surveillance, cyclotron, Nigeria
How to cite this paper
@article{1725494,
author = {Isa Sambo, Abuh Rafiu Abalaka},
title = {Radiation Surveillance in and around Cyclotron Facility in Nigeria},
journal = {Iconic Research And Engineering Journals},
year = {2026},
volume = {10},
number = {5},
pages = {4677-4684},
issn = {2456-8880},
url = {https://www.irejournals.com/formatedpaper/1725494.pdf},
abstract = {The cyclotron is an advanced particle accelerator that is mostly used to produce short-lived radionuclides or radioisotopes like 18F, 13N, and 11C for Positron Emission Tomography (PET). A cyclotron accelerator produced a well-defined, high-energy, and intensely charged particle beam (Livingston, 1954) with radionuclides produced when this beam hits the object. The aim of this research is to conduct a thorough radiological surveillance of the cyclotron building at the African Medical Center of Excellence (AMCE) in Abuja, Nigeria. A calibrated Ranger Radiation Alert meter was used at twenty-nine (29) survey locations across the facility to conduct a radiation and contamination survey. The results obtained show that the least radiation levels were obtained at synthesizer, emergency and exit main entrance with values of 0.01 μSv/h, 0.02 μSv/h and 0.03 μSv/h respectively. While highest radiation levels were obtained at T3 and T7 with values of 5.39 μSv/h and 5.89 μSv/h respectively. Although, these values are high but do not exceed limit of 7.5 μSv/h in the controlled area (Cyclotron Vault and Hot Lab) prescribed in Nigeria Basic Ionising Radiation Regulations of 2025. The study concluded that there was no indication of contamination in all the areas surveyed and recommended that regular radiation monitoring should be carried out periodically.},
keywords = {radiation, surveillance, cyclotron, Nigeria},
month = {November},
}