Home / Current Issue / Paper 1725499
Paper-Based Colorimetric Determination of Iron Using Cinnamon Nanoparticles and Copper Nitrate
Subject area: Science,Engineering and Technology · Area of research: Environmental Analytical Chemistry
Abstract
A simple paper-based colorimetric sensor for the determination of iron is described, in which filter-paper strips coated with cinnamon nanoparticles and copper nitrate give an olive-green spot on contact with Fe3+. The reagents are pre-loaded on the strip, so the sample is applied as a microlitre drop and the colour is read from a smartphone photograph: the red, green and blue (R, G, B) values of the spot are read with ImageJ software and converted into effective intensities against a blank strip. With 3% Cu(NO3)2 fixed throughout and strips given two dips in cinnamon nanoparticles, pH, the volume of iron solution, temperature and time were optimized. The best response was obtained at pH 7 with 2.86 µL of iron solution (159.6 µg Fe). The colour was established on contact at room temperature and stayed stable for 30 min, so no heating, incubation or timing is needed, and the strip responded to Fe3+ down to 100 ppm (mg/L). Unlike methods in which a colour reagent must be added to every sample or microfluidic channels must be patterned, the strip needs only 2.86 µL of sample, uses a natural-product reagent and requires nothing more than a smartphone camera and free image-analysis software, which makes it a simple and efficient tool for the determination of iron in water.
Keywords
cinnamon nanoparticles, colorimetric sensor, copper nitrate, iron, paper-based sensor
How to cite this paper
@article{1725499,
author = {Kranti Chaurasiya, Varsha Vishwakarma, Suparna Gosh, Ruchi Dubey Sharma},
title = {Paper-Based Colorimetric Determination of Iron Using Cinnamon Nanoparticles and Copper Nitrate},
journal = {Iconic Research And Engineering Journals},
year = {2026},
volume = {10},
number = {5},
pages = {4669-4676},
issn = {2456-8880},
url = {https://www.irejournals.com/formatedpaper/1725499.pdf},
abstract = {A simple paper-based colorimetric sensor for the determination of iron is described, in which filter-paper strips coated with cinnamon nanoparticles and copper nitrate give an olive-green spot on contact with Fe3+. The reagents are pre-loaded on the strip, so the sample is applied as a microlitre drop and the colour is read from a smartphone photograph: the red, green and blue (R, G, B) values of the spot are read with ImageJ software and converted into effective intensities against a blank strip. With 3% Cu(NO3)2 fixed throughout and strips given two dips in cinnamon nanoparticles, pH, the volume of iron solution, temperature and time were optimized. The best response was obtained at pH 7 with 2.86 µL of iron solution (159.6 µg Fe). The colour was established on contact at room temperature and stayed stable for 30 min, so no heating, incubation or timing is needed, and the strip responded to Fe3+ down to 100 ppm (mg/L). Unlike methods in which a colour reagent must be added to every sample or microfluidic channels must be patterned, the strip needs only 2.86 µL of sample, uses a natural-product reagent and requires nothing more than a smartphone camera and free image-analysis software, which makes it a simple and efficient tool for the determination of iron in water.},
keywords = {cinnamon nanoparticles, colorimetric sensor, copper nitrate, iron, paper-based sensor},
month = {November},
}