Abstract
A rapid, low-cost optical method based on digital RGB analysis is developed for the quantitative determination of fluoride (F−) in aqueous media, as a portable alternative to ion-selective electrode and spectrophotometric instrumentation. Image processing converts the colour of a spot into digital R, G and B values, enabling on-site screening around the WHO drinking water guideline value of 1.5 mg L−1. The paper-based analytical device (PAD) was prepared by immobilizing Rhodamine B (RhB) and aluminium chloride (AlCl3) on Whatman No. 40 filter paper by a simple dip-and-dry procedure. Sensing is proposed to rely on competitive ligand exchange, in which fluoride removes Al3+ from the pink [RhB–Al]3+ species as [AlF6]3− and bleaches the spot in proportion to the fluoride concentration. Under the optimized conditions (0.125% w/v RhB, 1% AlCl3, 1:1 ratio, four sample drops of 0.72 µL, pH 7, 40 °C and 5 min) the green-channel effective intensity magnitude (|Ag|) was used as the analytical signal. Over 0.05–1000 ppm, |Ag| followed a single log-linear relationship (|Ag| = 0.0289 log C + 0.255, R2 = 0.981) that can also be described by two linear segments: a steeper one at 0.05–0.5 ppm (three points) and a gentler one at 0.5–1000 ppm (R2 = 0.984). The practical detection limit of 0.05 ppm (about 2.6 µM) is 30 times lower than the WHO guideline value and lower than that of a reported wax-patterned microfluidic paper device. Ten coexisting ions (five anions and five cations) did not interfere up to 1000 ppm.
Keywords
paper-based analytical device, fluoride, Rhodamine B, aluminium chloride, colorimetric sensor, RGB analysis
References
[1] Xu J, Ma X, Li Z, Zhou T, Wang Y, Zhu J. Recent advances in paper-based microfluidic devices for heavy metal ion detection: a review. Micromachines (Basel). 2026;17(7):780. doi:10.3390/mi17070780
[2] Kant T, Shrivas K, Tejwani A, Tandey K, Sharma A, Gupta S. Progress in the design of portable colorimetric chemical sensing devices. Nanoscale. 2023;15(47):19016-38. doi:10.1039/d3nr03803c.
[3] Berasarte I, Albizu G, Santos WF, de Lima LF, Ostra M, Vidal M, de Araujo WR. Chemometrics and digital image colorimetry approaches applied to paper-based analytical devices: a review. Anal Chim Acta. 2025;1339:343577. doi:10.1016/j.aca.2024.343577.
[4] Hakim MS, Bilad MR. Colorimetric sensor for heavy metal ions detection: a short review. Evergreen. 2024;11(4):3127-42. Available from: https://www.tj.kyushu-u.ac.jp/evergreen/contents/EG2024-11_4_content/3127-3142.html
[5] Sharma RD, Joshi S, Amlathe S. A new optical analytical method for quantitative determination of lead on paper platform and its application for removal from aqueous sample. J Chem Pharm Res. 2015;7(6):27-36.
[6] World Health Organization. Guidelines for drinking-water quality: fourth edition incorporating the first and second addenda. Geneva: World Health Organization; 2022.
[7] National Health and Medical Research Council. Australian Drinking Water Guidelines: fluoride. Canberra: NHMRC; 2022. Available from: https://guidelines.nhmrc.gov.au/australian-drinking-water-guidelines/part-5/physical-chemical-characteristics/fluoride
[8] Bureau of Indian Standards (BIS). Drinking water specification, IS 10500:2012. New Delhi: BIS; 2012.
[9] Blasco Pascual I, Ortiz Gómez I, González-Alfaro S, Sánchez-Ruiz A, Orbe Payá I de, Capitán Vallvey L. Microfluidic paper-based analytical device for colorimetric detection of fluoride ion with smartphone readout. Microchem J. 2025:115675. doi:10.1016/j.microc.2025.115675.
[10] Mergu N, Singh AK, Gupta VK. Highly sensitive and selective colorimetric and off-on fluorescent reversible chemosensors for Al3+ based on the rhodamine fluorophore. Sensors (Basel). 2015;15(4):9097-111. doi:10.3390/s150409097.
[11] Mi Y, Liang D, Chen Y, Luo X, Xiang J. A rhodamine–quinoline type molecular switch as a highly selective sequential sensor for Al3+ and F− in aqueous solution. RSC Adv. 2014;4:42337-43. doi:10.1039/C4RA06473A.
How to cite this paper
@article{1725611,
author = {Beerbal Parmar, Varsha Vishwakarma, Dr. Ruchi Dubey Sharma, Dr. Sulbha Amlathe},
title = {A Rhodamine B–Aluminium Chloride Paper Strip for RGB-Based Quantitative Colorimetric Detection of Fluoride},
journal = {Iconic Research And Engineering Journals},
year = {2026},
volume = {10},
number = {5},
pages = {5414-5425},
issn = {2456-8880},
url = {https://www.irejournals.com/formatedpaper/1725611.pdf},
abstract = {A rapid, low-cost optical method based on digital RGB analysis is developed for the quantitative determination of fluoride (F−) in aqueous media, as a portable alternative to ion-selective electrode and spectrophotometric instrumentation. Image processing converts the colour of a spot into digital R, G and B values, enabling on-site screening around the WHO drinking water guideline value of 1.5 mg L−1. The paper-based analytical device (PAD) was prepared by immobilizing Rhodamine B (RhB) and aluminium chloride (AlCl3) on Whatman No. 40 filter paper by a simple dip-and-dry procedure. Sensing is proposed to rely on competitive ligand exchange, in which fluoride removes Al3+ from the pink [RhB–Al]3+ species as [AlF6]3− and bleaches the spot in proportion to the fluoride concentration. Under the optimized conditions (0.125% w/v RhB, 1% AlCl3, 1:1 ratio, four sample drops of 0.72 µL, pH 7, 40 °C and 5 min) the green-channel effective intensity magnitude (|Ag|) was used as the analytical signal. Over 0.05–1000 ppm, |Ag| followed a single log-linear relationship (|Ag| = 0.0289 log C + 0.255, R2 = 0.981) that can also be described by two linear segments: a steeper one at 0.05–0.5 ppm (three points) and a gentler one at 0.5–1000 ppm (R2 = 0.984). The practical detection limit of 0.05 ppm (about 2.6 µM) is 30 times lower than the WHO guideline value and lower than that of a reported wax-patterned microfluidic paper device. Ten coexisting ions (five anions and five cations) did not interfere up to 1000 ppm.},
keywords = {paper-based analytical device, fluoride, Rhodamine B, aluminium chloride, colorimetric sensor, RGB analysis},
month = {November},
}