Home / Current Issue / Paper 1725718
Building in the Mountains: Quality and Durability Controls for Precast Accommodation and Infrastructure at Trojena, Saudi Arabia
Subject area: Science,Engineering and Technology · Area of research: Materials Technology
Abstract
Trojena, the mountain destination planned within NEOM, places buildings and infrastructure between roughly 1,500 and 2,600 m above sea level, where winters fall below freezing, air pressure is markedly lower than at the coast and remote access favours factory-made components. Precast and modular construction suits such a site, but the conditions that make it attractive also threaten the durability of concrete and of the joints that hold precast elements together. This paper pairs a systematic integrative synthesis of thirty peer-reviewed sources dated 2020–2025 with a disclosed set of public documents on the project to develop a quality and durability control framework for precast accommodation and infrastructure at Trojena. The review groups the evidence into six themes: factory inspection, connections and grouting, air entrainment under reduced pressure, combined frost and salt attack, cold-weather strength verification, and thermal and shrinkage cracking at altitude. Evidence on the effect of low pressure on entrained air is mixed, with the clearest losses reported at pressures lower than those expected at Trojena, whereas evidence that early frost exposure and inadequate curing degrade strength and frost resistance is consistent. The resulting framework assigns hazard-specific controls to four gates, from factory release to in-service monitoring, and identifies maturity-based strength release, site-calibrated air content limits and connection grouting under temperature control as the highest-priority measures. The study relies on published evidence alone; neither project records nor field measurements from Trojena were available, so the framework should be calibrated through trial production before adoption.
References
[1] Al-Gahtani, K. S., Aldokhi, M. I., Alsanabani, N. M., Alotaibi, H. F., & Bin Mahmoud, A. A. (2024). The impact of dynamic risk interdependencies on the Saudi precast concrete industry. Buildings, 14(4), Article 875. https://doi.org/10.3390/buildings14040875
[2] Alshamrani, O. S. (2022). Integrated LCA-LCC assessment model of offsite, onsite, and conventional construction systems. Journal of Asian Architecture and Building Engineering, 21(5), 2058–2080. https://doi.org/10.1080/13467581.2021.1942001
[3] Chang, R., Zhang, N., & Gu, Q. (2023). A review on mechanical and structural performances of precast concrete buildings. Buildings, 13(7), Article 1575. https://doi.org/10.3390/buildings13071575
[4] Chen, X., Liu, X., Tian, B., Ge, Y., & Li, L. (2020). Effect of low atmospheric pressure on air entrainment in cement-based materials: An on-site experimental study at different elevations. Materials, 13(18), Article 3975. https://doi.org/10.3390/ma13183975
[5] Chen, Y., Al-Neshawy, F., & Punkki, J. (2021). Investigation on the effect of entrained air on pore structure in hardened concrete using MIP. Construction and Building Materials, 292, Article 123441. https://doi.org/10.1016/j.conbuildmat.2021.123441
[6] Cui, J., Duc Van, N., Zhang, F., & Hama, Y. (2022). Evaluation of applicability of minimum required compressive strength for cold weather concreting based on winter meteorological factors. Materials, 15(23), Article 8490. https://doi.org/10.3390/ma15238490
[7] Do, T. A., Hoang, T. T., Bui-Tien, T., Hoang, H. V., Do, T. D., & Nguyen, P. A. (2020). Evaluation of heat of hydration, temperature evolution and thermal cracking risk in high-strength concrete at early ages. Case Studies in Thermal Engineering, 21, Article 100658. https://doi.org/10.1016/j.csite.2020.100658
[8] Fang, M., Zhou, R., Ke, W., Tian, B., Zhang, Y., & Liu, J. (2022). Precast system and assembly connection of cement concrete slabs for road pavement: A review. Journal of Traffic and Transportation Engineering (English Edition), 9(2), 208–222. https://doi.org/10.1016/j.jtte.2021.10.003
[9] Hu, X., Liu, L., Liao, M., Li, M., Lu, C., Yao, Z., Huang, Q., & Zhuang, M.-L. (2024). Experimental investigations on the on-site crack control of pier concrete in high-altitude environments. Buildings, 14(11), Article 3445. https://doi.org/10.3390/buildings14113445
[10] Jiang, H. T., Zhang, X., Dong, J., Wei, L., & Mei, J. (2023). Mechanical properties of an improved grout for cementitious precast beam-column joints. Materials Research Express, 10(9), Article 095202. https://doi.org/10.1088/2053-1591/acf6fc
[11] Li, X., & Yang, P. (2021). Effect of low atmospheric pressure on bubble stability of air-entrained concrete. Advances in Civil Engineering, 2021(1), Article 5533437. https://doi.org/10.1155/2021/5533437
[12] Liu, J., Ergan, S., & Zhang, Q. (2024). An AprilTags-based approach for progress monitoring and quality control in modular construction. Buildings, 14(7), Article 2252. https://doi.org/10.3390/buildings14072252
[13] Liu, J., Tian, Q., Wang, Y., Li, H., & Xu, W. (2021). Evaluation method and mitigation strategies for shrinkage cracking of modern concrete. Engineering, 7(3), 348–357. https://doi.org/10.1016/j.eng.2021.01.006
[14] Narantogtokh, B., Nishiwaki, T., & Pushpalal, D. (2022). Current issues and questionnaire survey of cold weather concreting in Mongolia. Buildings, 12(8), Article 1262. https://doi.org/10.3390/buildings12081262
[15] Reichenbach, S., & Kromoser, B. (2021). State of practice of automation in precast concrete production. Journal of Building Engineering, 43, Article 102527. https://doi.org/10.1016/j.jobe.2021.102527
[16] Ren, J., & Lai, Y. (2021). Study on the durability and failure mechanism of concrete modified with nanoparticles and polypropylene fiber under freeze-thaw cycles and sulfate attack. Cold Regions Science and Technology, 188, Article 103301. https://doi.org/10.1016/j.coldregions.2021.103301
[17] Shin, J., & Choi, B. (2022). Design and implementation of quality information management system for modular construction factory. Buildings, 12(5), Article 654. https://doi.org/10.3390/buildings12050654
[18] Skrzypczak, I. (2023). Statistical quality inspection methodology in production of precast concrete elements. Materials, 16(1), Article 431. https://doi.org/10.3390/ma16010431
[19] Tekle, B. H., Al-Deen, S., Anwar-Us-Saadat, M., Willans, N., Zhang, Y., & Lee, C. K. (2022). Use of maturity method to estimate early age compressive strength of slab in cold weather. Structural Concrete, 23(2), 1176–1190. https://doi.org/10.1002/suco.202000693
[20] Tripathi, A., Kaushal, I., Revolti, A., Benedetti, L., & Dallasega, P. (2025). Digital twin driven quality control in smart mobile factories: A framework in precast manufacturing. Procedia CIRP, 134, 801–806. https://doi.org/10.1016/j.procir.2025.02.194
[21] Tsz Wai, C., Wai Yi, P., Ibrahim Olanrewaju, O., Abdelmageed, S., Hussein, M., Tariq, S., & Zayed, T. (2023). A critical analysis of benefits and challenges of implementing modular integrated construction. International Journal of Construction Management, 23(4), 656–668. https://doi.org/10.1080/15623599.2021.1907525
[22] Utepov, Y., Aniskin, A., Tulebekova, A., Aldungarova, A., Zharassov, S., & Sarsembayeva, A. (2021). Complex maturity method for estimating the concrete strength based on curing temperature, ambient temperature and relative humidity. Applied Sciences, 11(16), Article 7712. https://doi.org/10.3390/app11167712
[23] Wang, N., Liu, Q., Xia, Y., Li, J., Lu, Z., Xu, Y., Zhong, W., & Lin, Y. (2023). Physical properties and hydration characteristics of low-heat Portland cement at high-altitude. Materials, 16(8), Article 3110. https://doi.org/10.3390/ma16083110
[24] Wuni, I. Y., & Shen, G. Q. (2023). Exploring the critical production risk factors for modular integrated construction projects. Journal of Facilities Management, 21(1), 50–68. https://doi.org/10.1108/jfm-03-2021-0029
[25] Zalegowski, K. (2025). Pore structure influence on properties of air-entrained concrete. Materials, 18(12), Article 2885. https://doi.org/10.3390/ma18122885
[26] Zhang, G., Cao, F., Li, T., Sun, C., Guo, W., Ma, Y., Ren, F., Wang, Y., Si, W., & Ma, B. (2025). State of the art on prevention and control measures of thermal cracks in mass concrete. Sustainability, 17(24), Article 11301. https://doi.org/10.3390/su172411301
[27] Zhang, K., Guo, A., Yu, Y., Yang, B., Yu, B., & Xie, C. (2023). Freeze–thaw damage degradation model and life prediction of air-entrained concrete in multi-year permafrost zone. Materials, 16(24), Article 7703. https://doi.org/10.3390/ma16247703
[28] Zhang, Z., Zhang, Y., & Zhu, P. (2022). Flexural behavior of precast RC deck panels with cast-in-place UHPFRC connection. Coatings, 12(8), Article 1183. https://doi.org/10.3390/coatings12081183
[29] Zhou, J., Wang, G., Liu, P., Guo, X., & Xu, J. (2022). Concrete durability after load damage and salt freeze–thaw cycles. Materials, 15(13), Article 4380. https://doi.org/10.3390/ma15134380
[30] Zohourian, M., Pamidimukkala, A., Kermanshachi, S., & Almaskati, D. (2025). Modular construction: A comprehensive review. Buildings, 15(12), Article 2020. https://doi.org/10.3390/buildings15122020
How to cite this paper
@article{1725718,
author = {Muhammad Ismail},
title = {Building in the Mountains: Quality and Durability Controls for Precast Accommodation and Infrastructure at Trojena, Saudi Arabia},
journal = {Iconic Research And Engineering Journals},
year = {2026},
volume = {10},
number = {5},
pages = {5966-5978},
issn = {2456-8880},
url = {https://www.irejournals.com/formatedpaper/1725718.pdf},
abstract = {Trojena, the mountain destination planned within NEOM, places buildings and infrastructure between roughly 1,500 and 2,600 m above sea level, where winters fall below freezing, air pressure is markedly lower than at the coast and remote access favours factory-made components. Precast and modular construction suits such a site, but the conditions that make it attractive also threaten the durability of concrete and of the joints that hold precast elements together. This paper pairs a systematic integrative synthesis of thirty peer-reviewed sources dated 2020–2025 with a disclosed set of public documents on the project to develop a quality and durability control framework for precast accommodation and infrastructure at Trojena. The review groups the evidence into six themes: factory inspection, connections and grouting, air entrainment under reduced pressure, combined frost and salt attack, cold-weather strength verification, and thermal and shrinkage cracking at altitude. Evidence on the effect of low pressure on entrained air is mixed, with the clearest losses reported at pressures lower than those expected at Trojena, whereas evidence that early frost exposure and inadequate curing degrade strength and frost resistance is consistent. The resulting framework assigns hazard-specific controls to four gates, from factory release to in-service monitoring, and identifies maturity-based strength release, site-calibrated air content limits and connection grouting under temperature control as the highest-priority measures. The study relies on published evidence alone; neither project records nor field measurements from Trojena were available, so the framework should be calibrated through trial production before adoption.},
month = {November},
}