Home / Current Issue / Paper 1725862
Exploring The Principles of Daylighting in The Design of a Skills Acquisition Centre in Jos East, Plateau State, Nigeria
Subject area: Science,Engineering and Technology · Area of research: Architecture
DOI: 10.64388/ire1725862
Abstract
Daylighting is central to the environmental performance of skills-acquisition facilities. Workshops and learning spaces depend on sufficient, well-distributed illumination to support practical activities and safe task performance. This article examines daylighting strategies in four vocational and skills-training facilities and considers their implications for the architectural design of a proposed skills acquisition centre in Jos East, Plateau State, Nigeria. It adopts an exploratory multiple-case-study approach based on documented site observations, photographs, sketches, descriptive appraisals, checklist records and workshop illuminance readings. The cases comprise the Women in Agriculture and Youth Empowerment Foundation in Jos, Government Science and Technical School in Bukuru, Sani Abacha Youth Centre in Kano, and Gebhard Müller Vocational Training School in Germany. The comparative appraisal considers orientation, window configuration, skylights, clerestories, roof monitors, light shelves, solar tubes, internal surface reflectance, shading and glare control. Recalculation of the reported illuminance readings gives mean values across the four cases of approximately 384 lx at window zones, 319 lx at mid-room zones and 278 lx at rear zones. These figures show a progressive reduction in measured illuminance with increasing distance from the window wall. The international case documents a more integrated combination of atria, skylights, high-level openings and automated external shading. By comparison, the Nigerian cases rely mainly on side-lighting, indicating scope to improve daylight distribution and solar control. The available documentation, however, does not fully identify the measurement instrument, its calibration, sensor height, measurement dates, sky conditions, electric-lighting status or checklist scoring rules. The illuminance values are therefore treated as descriptive spot readings, not evidence of compliance with a lighting standard; the inconsistent checklist percentages are likewise excluded as validated performance scores. The article recommends climate-responsive orientation, carefully designed bilateral and high-level openings, selective top-lighting, external shading, reflective matte finishes, and formal daylight simulation followed by field verification for the proposed centre.
Keywords
daylighting, passive design, skills acquisition centre, vocational education, illuminance, visual comfort, Jos East, Nigeria
References
[1] Ayoosu, M. I., Utsaha, A. L., Gabriel, K. E., Vishigh, A. M. M., Tuleun, M. E., & Sen, I. G. (2025). Daylighting performance assessment: A review of methodologies. Path of Science, 11(1). https://doi.org/10.22178/pos.113-16
[2] British Standards Institution. (2021). BS EN 12464-1:2021: Light and lighting—Lighting of work places—Part 1: Indoor work places. BSI.
[3] European Committee for Standardization. (2021). EN 12464-1:2021: Light and lighting—Lighting of work places—Part 1: Indoor work places. CEN.
[4] Illuminating Engineering Society. (2023). ANSI/IES LM-83-23: Approved method: IES spatial daylight autonomy (sDA) and annual sunlight exposure (ASE). IES.
[5] Kalaimathy, K., Priya, R. S., Rajagopal, P., & Pradeepa, C. (2023). A review of daylighting calculation metrics, variables and methods in evaluating the daylight performance of a residential building. AIP Conference Proceedings, 2813, 020016. https://doi.org/10.1063/5.0156987
[6] Krasić, S., Pejić, P., & Mitković, P. (2013). Significance of daylight in the design and construction of buildings. Građevinar, 65(9), 833–840. https://doi.org/10.14256/JCE.869.2013
[7] Lim, Y.-W., Kandar, M. Z., Ahmad, M. H., Ossen, D. R., & Abdullah, A. M. (2012). Building façade design for daylighting quality in a typical government office building. Building and Environment, 57, 194–204. https://doi.org/10.1016/j.buildenv.2012.04.015
[8] Lim, Y.-W., Ahmad, M. H., & Ossen, D. R. (2013). Internal shading for efficient tropical daylighting in Malaysian contemporary high-rise open-plan offices. Indoor and Built Environment, 22(6), 932–951. https://doi.org/10.1177/1420326X12463024
[9] Ticleanu, C., Howlett, G., Flores-Villa, L., & Le Gall, G. (2023). RI07: Daylight calculation methods. Chartered Institution of Building Services Engineers (CIBSE).
[10] Galatioto, A., & Beccali, M. (2016). Aspects and issues of daylighting assessment: A review study. Renewable and Sustainable Energy Reviews, 66, 852–860. https://doi.org/10.1016/j.rser.2016.08.018
[11] Tregenza, P., & Mardaljevic, J. (2018). Daylighting buildings: Standards and the needs of the designer. Lighting Research & Technology, 50(1), 63–79. https://doi.org/10.1177/1477153517740611
How to cite this paper
@article{1725862,
author = {Bitrus Solomon Babangida, Usman B. Wakawa, Haruna Abdul Usman, Yakubu, Salviya Tarfa, Yakubu Yau Gital},
title = {Exploring The Principles of Daylighting in The Design of a Skills Acquisition Centre in Jos East, Plateau State, Nigeria},
journal = {Iconic Research And Engineering Journals},
year = {2026},
volume = {10},
number = {5},
pages = {7453-7462},
issn = {2456-8880},
url = {https://www.irejournals.com/formatedpaper/1725862.pdf},
abstract = {Daylighting is central to the environmental performance of skills-acquisition facilities. Workshops and learning spaces depend on sufficient, well-distributed illumination to support practical activities and safe task performance. This article examines daylighting strategies in four vocational and skills-training facilities and considers their implications for the architectural design of a proposed skills acquisition centre in Jos East, Plateau State, Nigeria. It adopts an exploratory multiple-case-study approach based on documented site observations, photographs, sketches, descriptive appraisals, checklist records and workshop illuminance readings. The cases comprise the Women in Agriculture and Youth Empowerment Foundation in Jos, Government Science and Technical School in Bukuru, Sani Abacha Youth Centre in Kano, and Gebhard Müller Vocational Training School in Germany. The comparative appraisal considers orientation, window configuration, skylights, clerestories, roof monitors, light shelves, solar tubes, internal surface reflectance, shading and glare control. Recalculation of the reported illuminance readings gives mean values across the four cases of approximately 384 lx at window zones, 319 lx at mid-room zones and 278 lx at rear zones. These figures show a progressive reduction in measured illuminance with increasing distance from the window wall. The international case documents a more integrated combination of atria, skylights, high-level openings and automated external shading. By comparison, the Nigerian cases rely mainly on side-lighting, indicating scope to improve daylight distribution and solar control. The available documentation, however, does not fully identify the measurement instrument, its calibration, sensor height, measurement dates, sky conditions, electric-lighting status or checklist scoring rules. The illuminance values are therefore treated as descriptive spot readings, not evidence of compliance with a lighting standard; the inconsistent checklist percentages are likewise excluded as validated performance scores. The article recommends climate-responsive orientation, carefully designed bilateral and high-level openings, selective top-lighting, external shading, reflective matte finishes, and formal daylight simulation followed by field verification for the proposed centre.},
keywords = {daylighting, passive design, skills acquisition centre, vocational education, illuminance, visual comfort, Jos East, Nigeria},
month = {November},
doi = {https://doi.org/10.64388/ire1725862}
}