Home / Current Issue / Paper 1714247
Review on: Performance Analysis of HIP Continuous Passive Motion Machine for Post Operative Rehabilitation
Subject area: Science,Engineering and Technology · Area of research: Mechanical Engineering
DOI: https://doi.org/10.64388/IREV9I8-1714247
Abstract
This review paper presents an analytical overview of the performance and clinical effectiveness of Continuous Passive Motion (CPM) machines developed for hip rehabilitation following surgical procedures. The study consolidates insights from recent clinical trials, biomechanical assessments, and design evaluations to understand the therapeutic potential and limitations of CPM therapy in post-operative recovery. Evidence indicates that hip CPM devices can enhance early joint mobility, reduce pain, and support tissue healing during the initial recovery phase; however, long-term functional outcomes often align with those achieved through traditional physiotherapy. The paper further emphasizes the importance of ergonomic design, precise alignment, and individualized motion control to optimize therapeutic benefits and minimize discomfort. Despite encouraging results, variations in patient response and the absence of standardized clinical protocols highlight the need for further research. Future advancements integrating sensor technology, feedback systems, and patient-specific customization could transform hip CPM devices into more adaptive and effective rehabilitation tools.
Keywords
Continuous Passive Motion, Hip Rehabilitation, Post-Operative Recovery, Physiotherapy, Biomechanical Design, Performance Analysis.
References
[1] Y. Zhu et al., “New wearable walking-type continuous passive motion device for postsurgery walking rehabilitation,” Proc Inst Mech Eng H, vol. 227, no. 7, pp. 733–745, Jul. 2013, doi: 10.1177/0954411913481557.
[2] T. Deaconescu, A. Deaconescu, and I. Petre, “Continuous passive motion-based rehabilitation equipment for the recovery of lower limb bearing joints,” 2014.
[3] Z. Jia, Y. Zhang, W. Zhang, C. Xu, and W. Liu, “Efficacy and safety of continuous passive motion and physical therapy in recovery from knee arthroplasty: a systematic review and meta-analysis,” Dec. 01, 2024, BioMed Central Ltd. doi: 10.1186/s13018-024-04536-y.
[4] A. Gupta and A. Al-Anbuky, “Iot-based patient movement monitoring: The post-operative hip fracture rehabilitation model,” Future Internet, vol. 13, no. 8, Aug. 2021, doi: 10.3390/fi13080195.
[5] R. J. van Arkel, A. A. Amis, and J. R. T. Jeffers, “The envelope of passive motion allowed by the capsular ligaments of the hip,” J Biomech, vol. 48, no. 14, pp. 3803–3809, Nov. 2015, doi: 10.1016/j.jbiomech.2015.09.002.
[6] H. H. M. Al-Almoodi, N. Z. Azlan, I. Shahdad, and N. Kamarudzaman, “Continuous Passive Motion Machine for Elbow Rehabilitation,” International Journal of Robotics and Control Systems, vol. 1, no. 3, pp. 402–415, 2021, doi: 10.31763/ijrcs.v1i3.446.
[7] B. C. Lee et al., “Clinical evaluation of usefulness and effectiveness of sitting type continuous passive motion machines in patients with total knee arthroplasty: a study protocol for a single-blinded randomized controlled trial,” BMC Musculoskelet Disord, vol. 23, no. 1, Dec. 2022, doi: 10.1186/s12891-022-05507-2.
[8] Y. Yang, J. Wang, X. Y. Zhang, L. Dong, A. F. Liu, and C. Y. Li, “The Effect of Continuous Passive Motion in Patients Treated With Total Knee Arthroplasty for Osteoarthritis: A Systematic Review and Meta-analysis of Randomized Controlled Trials,” Am J Phys Med Rehabil, vol. 100, no. 12, pp. 1160–1169, Dec. 2021, doi: 10.1097/PHM.0000000000001718.
[9] S. B. White, D. A. Bemben, A. W. Knehans, and M. G. Bemben, “Effect of Continuous Passive Motion (Machine-Assisted) Exercise as an Alternative Form of Training on Physiological Profiles of Women Aged 40-65 Years,” 2005.
[10] IEEE Staff, 2011 2nd International Conference on Instrumentation, Communications, Information Technology, and Biomedical Engineering. IEEE, 2011.
[11] Y. Pititheeraphab, T. Angsuwatanakul, C. Pintavirooj, and T. Khemanuwong, “Design And Construction Of Continuous Passive Motion (Cpm) For Arm Rehabilitation Device.”
[12] S. Liu, K. Shivdasani, M. Scheidt, A. L. Chen, N. G. Garbis, and D. H. Salazar, “Surgical management of elbow heterotopic ossification: postoperative outcomes with and without continuous passive motion rehabilitation,” JSES Int, vol. 9, no. 3, pp. 924–928, May 2025, doi: 10.1016/j.jseint.2025.02.002.
[13] S. Tangjitsitcharoen and H. Lohasiriwat, “Redesign of a continuous passive motion machine for total knee replacement therapy,” J Health Res, vol. 33, no. 2, pp. 106–118, Apr. 2019, doi: 10.1108/JHR-06-2018-0024.
[14] F. Coutts, D. Hewetson, and J. Matthews, “Continuous Passive Motion of the Knee Joint: Use at The Royal National Orthopaedic Hospital, Stanmore,” Physiotherapy (United Kingdom), vol. 75, no. 7, pp. 427–431, 1989, doi: 10.1016/S0031-9406(10)62616-8.
[15] R. Dwornicka and I. Dominik, “Design of Continuous Passive Motion Machine Based on Kinematic Model of Lower Limb,” Applied Mechanics and Materials, vol. 712, pp. 93–97, Jan. 2015, doi: 10.4028/www.scientific.net/amm.712.93.
[16] F. Can and M. Alpaslan, “Continuous passive motion on pain management in patients with total knee arthroplasty,” Pain Clinic, vol. 15, no. 4, pp. 479–485, 2003, doi: 10.1163/156856903770196890.
[17] R. L. Worland, J. Arredondo, F. Angles, F. Lopez-Jimenez, and D. E. Jessup, “Home Continuous Passive Motion Machine Versus Professional Physical Therapy Following Total Knee Replacement,” 1998.
[18] X. Yang, G. hong Li, H. jie Wang, and C. yuan Wang, “Continuous Passive Motion After Total Knee Arthroplasty: A Systematic Review and Meta-analysis of Associated Effects on Clinical Outcomes,” Sep. 01, 2019, W.B. Saunders. doi: 10.1016/j.apmr.2019.02.001.
[19] M. Richter, T. Trzeciak, and M. Kaczmarek, “Effect of continuous passive motion on the early recovery outcomes after total knee arthroplasty,” Int Orthop, vol. 46, no. 3, pp. 549–553, Mar. 2022, doi: 10.1007/s00264-021-05245-5.
[20] A. Mau-Moeller, M. Behrens, S. Finze, S. Bruhn, R. Bader, and W. Mittelmeier, “The effect of continuous passive motion and sling exercise training on clinical and functional outcomes following total knee arthroplasty: A randomized active-controlled clinical study,” Health Qual Life Outcomes, vol. 12, no. 1, May 2014, doi: 10.1186/1477-7525-12-68.
[21] M. Munsch, S. P. Vajapey, W. K. Vasileff, T. Ellis, J. DeWitt, and J. Ryan, “Use of continuous passive motion device after arthroscopic hip surgery decreases post-operative pain: A randomized controlled trial,” J Clin Orthop Trauma, vol. 23, Dec. 2021, doi: 10.1016/j.jcot.2021.101646.
[22] K. L. Adler, P. C. Cook, P. R. Geisler, Y. M. Yen, and B. D. Giordano, “Current Concepts in Hip Preservation Surgery: Part II—Rehabilitation,” Sports Health, vol. 8, no. 1, pp. 57–64, Jan. 2016, doi: 10.1177/1941738115577621.
[23] T. T. Deaconescu and A. I. Deaconescu, “Pneumatic muscle actuated equipment for continuous passive motion,” in AIP Conference Proceedings, 2009, pp. 311–321. doi: 10.1063/1.3256258.
[24] M. L. Voight, K. Robinson, L. Gill, and K. Griffin, “Postoperative rehabilitation guidelines for hip arthroscopy in an active population,” Sports Health, vol. 2, no. 3, pp. 222–230, May 2010, doi: 10.1177/1941738110366383.
[25] J. A. Herbold, K. Bonistall, and M. Blackburn, “Effectiveness of continuous passive motion in an inpatient rehabilitation hospital after total knee replacement: A matched cohort study,” PM and R, vol. 4, no. 10, pp. 719–725, Oct. 2012, doi: 10.1016/j.pmrj.2012.07.004.
[26] R. Sauber, G. Saborio, B. M. Nickel, B. R. Kivlan, and J. J. Christoforetti, “Pendulum Exercises After Hip Arthroscopy: A Video Technique,” Arthrosc Tech, vol. 5, no. 4, pp. e897–e900, Aug. 2016, doi: 10.1016/j.eats.2016.04.013.
How to cite this paper
@article{1714247,
author = {Bhavesh Wasnik, Dr. M. Sohail Pervez, Dr. R. N Dehankar},
title = {Review on: Performance Analysis of HIP Continuous Passive Motion Machine for Post Operative Rehabilitation},
journal = {Iconic Research And Engineering Journals},
year = {2026},
volume = {9},
number = {8},
pages = {606-610},
issn = {2456-8880},
url = {https://www.irejournals.com/formatedpaper/1714247.pdf},
abstract = {This review paper presents an analytical overview of the performance and clinical effectiveness of Continuous Passive Motion (CPM) machines developed for hip rehabilitation following surgical procedures. The study consolidates insights from recent clinical trials, biomechanical assessments, and design evaluations to understand the therapeutic potential and limitations of CPM therapy in post-operative recovery. Evidence indicates that hip CPM devices can enhance early joint mobility, reduce pain, and support tissue healing during the initial recovery phase; however, long-term functional outcomes often align with those achieved through traditional physiotherapy. The paper further emphasizes the importance of ergonomic design, precise alignment, and individualized motion control to optimize therapeutic benefits and minimize discomfort. Despite encouraging results, variations in patient response and the absence of standardized clinical protocols highlight the need for further research. Future advancements integrating sensor technology, feedback systems, and patient-specific customization could transform hip CPM devices into more adaptive and effective rehabilitation tools.},
keywords = {Continuous Passive Motion, Hip Rehabilitation, Post-Operative Recovery, Physiotherapy, Biomechanical Design, Performance Analysis.},
month = {February},