Home / Current Issue / Paper 1702667
Implementation and Monitoring Of Transformer-Less Unified Power Flow Controller on OLED Display by Using Matlab
Subject area: Science,Engineering and Technology · Area of research: Electrical Engineering
Abstract
Monitoring & Control of Transformer-less Unified Power Flow Controller on OLED Display. Flexible AC Transmission (FACTS) Devices were introduced. It is well that Unified PFC (Unified Power flow controllers) are the most versatile FACTS device that can be used to activate power flow control between synchronous grids. The convention UPFC that consists of Two back-to-back inverter is connecting with series and shunt transformers used for real power and reactive power exchange between grids to Unified-PFC and monitoring on LED and LCD Monitoring device which consume high power while monitoring. In Transformer less new FACTS, the device is used to overcome the problem of convention UPFC such as bulky, large size, Zig-Zag transformer, high loss of power in monitoring, Clearance appearance, having a slow dynamic response, isolation. Although the new transformer-less UPFC to remove series and shunt transformers to achieve the desired power. Onboard OLED monitoring with Transformer-less UPFC several advantages over traditional technology, such as Transformer-less, low weight, high gain, heavy efficiency, adequate budget & FDS- Fast Dynamic Response.
References
[1] L.M. Liu, P.C. Zhu, Y. Kang, and J. Chen, “Power-Flow Control Performance Analysis of a Unified Power-Flow Controller in a Novel Control scheme”, IEEE Transactions on Power Delivery, vol. 22, pp. 1613-1619, 2007.
[2] Kannas, S Jayaram, and M.A. Sharma, “Real and Reactive Power Coordination for a Unified Power Flow Controller”, IEEE Transactions on Power System, vol.19, pp. 1454- 1461, 2014.
[3] F.Z. Peng, J.S. Lai, W. McKeever, and J. VanCoevering, “A multilevel voltage-source inverter with separate DC sources for static VAR generation”, IEEE Transactions on Industry Applications, vol. 32, pp. 1130-1138, 2015.
[4] T. Yang, Y Lui, X.R. Wang, D. Gunasekaran, U. Karki, and F.Z. Peng, “Modulation and Control of Transformer-less UNIFIED-PFC”, IEEE Transactios of Industry applications, vol. PP, pp. 1-1, 2015.
[5] S.T. Yang, S Zhang, X.R. Wang D. Gunasekaran, and F.Z. Peng, “Optimization of fundamental frequency modulation for cascaded multilevel inverter-based transformer- less UNIFIED-PFC”, in 2014 IEEE Energy Conversation Congress and Exposition (ECCE), 2014, pp. 4647-4652.
[6] C.D. Schauder, L. Gyugyi, M.R. Lund, D.M. Hamai, T.R. Reitman, D.R. Torgerson, and A. Edris, “Operation of the Unified power flow controller (UNIFIED-PFC) under practical cinstraints”, IEEE Trans. Power Del., vol. 13, no.2, pp. 630-639, 1998
[7] Kim S.Y., Yoon J.S., Chang B.H., Baek D.H., “The operation experience of KEPCO INIFIED- PFC”, in the processing of the Eighth International Conference on Electrical Machines and Systems, 2005, pp. 2502-2505
How to cite this paper
@article{1702667,
author = {Ankit Bishnoi},
title = {Implementation and Monitoring Of Transformer-Less Unified Power Flow Controller on OLED Display by Using Matlab},
journal = {Iconic Research And Engineering Journals},
year = {2021},
volume = {4},
number = {10},
pages = {99-102},
issn = {2456-8880},
url = {https://www.irejournals.com/formatedpaper/1702667.pdf},
abstract = {Monitoring & Control of Transformer-less Unified Power Flow Controller on OLED Display. Flexible AC Transmission (FACTS) Devices were introduced. It is well that Unified PFC (Unified Power flow controllers) are the most versatile FACTS device that can be used to activate power flow control between synchronous grids. The convention UPFC that consists of Two back-to-back inverter is connecting with series and shunt transformers used for real power and reactive power exchange between grids to Unified-PFC and monitoring on LED and LCD Monitoring device which consume high power while monitoring. In Transformer less new FACTS, the device is used to overcome the problem of convention UPFC such as bulky, large size, Zig-Zag transformer, high loss of power in monitoring, Clearance appearance, having a slow dynamic response, isolation. Although the new transformer-less UPFC to remove series and shunt transformers to achieve the desired power. Onboard OLED monitoring with Transformer-less UPFC several advantages over traditional technology, such as Transformer-less, low weight, high gain, heavy efficiency, adequate budget & FDS- Fast Dynamic Response.},
month = {April},
}